CCpilot X1400
Product revision: 1.0
Technical manual
2022-12-20
www.crosscontrol.com
17
Mic In
Optional feature
HMI
Status LED
Tricolour LED status indicator with configurable behaviour
Software
Operating system
Windows 10
Additional software
CCsettings, CCvideo. API’s are available to access settings, video
and other equipment from software
Display
14.1”
Type
TFT-LCD, 16:10, anti-glare coated
Resolution
1280 x 800
Colour Depth
16.7M
Backlight
LED, 600 cd/m
2
Power
Supply
Supply Voltage
12 or 24 V nominal, Continuous operation 10V to 34V
Power Consumption
24 V - Max 6 A at peak load. Typical 1,4 A at idle.
12 V - Max 12 A at peak load. Typical 2,5 A at idle.
7.3.
Environmental tolerance
Environmental Test
Standard
Dry Heat
IEC 60068-2-2
Operating: +55°C, 24h
Storage: +60°C, 24h
Damp Heat
IEC 60068-2-30
Operation: +25°C / +55°C
>93% RH 6*24h
Cold
IEC 60068-2-1
Operating: -25°C, 24h
Storage: -40°C, 24h
Change of temperature
IEC 60068-2-14
-25°C to +30°C, 5C/min
3hr hold time, 20 cycles
Vibration
IEC 60068-2-64
0,01 g2/Hz 5-200 Hz 3x1h
Shock
IEC 60068-2-29
5 g / 11ms 3x ±1000 bumps
30 g / 6ms 3x ± 3 bumps
EMC Electrical Transient
ISO 13766-1
ISO 7637-2
Pulse:
1. -450 V
2a. +55 V
2b. +20 V
3a. -220 V
3b. +220 V
4. -4 V (12V system)
5.+70 V
EMC Immunity, ESD
ISO 10605
±15 kV air, ±8 kV contact
EMC Immunity, RF
ISO 11452-2
ISO 11452-4
RF electromagnetic field
200-2000 MHz, 100 V/m
Bulk Current Injection
20-250 MHz, 100 mA