CXM539 User’s Manual
Doc.# 6001-0014 Rev1.2
Page 11
6 Appendix A. CXM539 command spec
6.1
Main Commands (available in all modes)
All Commands Must be followed by a return.
All changes to the mode value are saved as the power-up mode.
M?
Send the current mode value.
M=R
All Data is Sent as raw A/D Counts in ASCII four digit
Hex values or Binary Values depending on the current
mode.
M=C
All Data is Sent as Gammas, Formatted as base Ten fixed
point Text or Binary Values depending on the current
mode.
M=B
Set Data is Formatted as Binary Numbers.
M=T
Set Data is Formatted as Text Numbers.
M=E
Send a checksum with all Data.
M=N
Don't Send a checksum.
A
Start Auto Send Data.
S
Stop Auto Send.
D
Send the current Data Value.
B?
Send the run mode Baud Rate.
B=#####
Set Run Mode Baud Rate 300 - 76800 Baud is accepted.
In Config Mode the baud rate is always 9600.
P?
Display the current pacing value.
P=####
Set a Pacing value to slow the data rate.
E?
Send All EEROM Data.
E####
Send EEROM Data followed by 4 hex digits address and
optional 2 digits representing the number of bytes to send.
W####XX
Write EEROM Data followed by a 4 hex digit address
and 2 hex digits of Data.
C
Reset and Calibrate A/D(s).
I
Send ID and many internal values.
*
Reset and Restart Sensor.
?
Display Help.