30" GAS RANGE INSTALLATION INSTRUCTIONS

(For gas venturi models with electric ignition)

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Clearances and Dimensions

1.

Location—Check location where the range will be
installed. Check for proper electrical and gas supply,
and the stability of the floor.

2.

Dimensions that are shown must be used. Given
dimensions provide minimum clearance. Contact
surface must be solid and level.

Français - pages 9-16

 If the information in this manual is not followed

exactly, a fire or explosion may result causing property
damage, personal injury or death.

FOR YOUR SAFETY:

Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone
in your building.

• Immediately call your gas supplier from a neighbor's

phone.  Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire

department.

Installation and service must be performed by a qualified
installer, service agency or the gas supplier.

Note: For appliances installed in the
Commonwealth of Massachusetts see
page 2.

Refer to your serial plate for

applicable agency certification

p/n 316469109 EN/FR (1002)

Provide Proper Fuel Type

Before Proceeding:

 Your appliance was preset at the

factory to operate on Natural Gas.

Please note: 

For operation at elevations above 2000 ft.

(610m), appliance rating shall be reduced at the rate of 4
percent for each 1000 ft. (305m) above sea level.

 DO NOT

 attempt to convert this range to

L.P. (Propane)  without the proper L.P. (Propane)
conversion kit provided with this appliance or obtained from
your dealer. Follow all instructions provided with the
conversion kit.

Summary of Contents for CRG3120LW

Page 1: ... TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installationandservicemustbeperformedbyaqualified installer service agency or the gas supplier Note For appl...

Page 2: ...children alone or unattended in the area where an appliance is in use As children grow teachthemtheproper safeuseofallappliances Neverleave the oven door open when the range is unattended Stepping leaning or sitting on the doors ordrawersofthisrangecanresultinseriousinjuriesand can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children co...

Page 3: ...ip brackets must also be moved and installed with the range Instructions are provided for installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing A LocatetheBracketUsingtheT...

Page 4: ...ion air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches Leaktestingoftheapplianceshallbeconductedaccordingto the ...

Page 5: ...ever be over 14 water column WhenproperlyadjustedforNaturalGasthemanifoldpressure is 4 For LP Propane Gas the manifold pressure is 10 DO NOT allow regulator to turn on pipe when tightening fittings a Installanexternalmanualgasshut offvalvetogassupply lineinanaccessiblelocationoutsideoftherange Besure you know where and how to shut off the gas supply to the range b Install1 2 flareunionadaptertopre...

Page 6: ...s Becauseofpotentialsafetyhazardsundercertainconditions we strongly recommend against the use of any extension cord However if you still elect to use an extension cord it is absolutely necessary that it be a UL listed 3 wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than thebranchcircuitrating Suchextensioncordsa...

Page 7: ...s the electrically controlled oven valve will open and flame will appear at the oven burner There is a time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner When the oven reaches the dial setting the glowing igniter will go off The burner flame will go out in 20 to 30 seconds after the igniter goes OFF To maintain any given oven temperature ...

Page 8: ...des common occurrences that are not the result of defective workmanship or materials in this appliance Refer to the warranty in your Owner s Guide for our toll free service number and address Please call or write if you have inquiries about your range product and or need to order parts Care Cleaning and Maintenance Refer to the Owner s Guide for operating and cleaning instructions If removing the ...