TYPE OF WATER 

If any liquid contains stringy or large material that may cause obstruction, a suction 
strainer should be used. If the pump is needed for chemicals, you must check the pump 
compatibility with your local dealer. 

FIXED INSTALLATIONS 

 

In some installations and only if the pump is used under stressful conditions, such as 
pumping uphill for long distances, the pump may not work on start up. 

To rectify this, a check valve should be installed between the pump and the pipe and a 
gate valve should be installed on the pump discharge. If it still fails, open the valve to 
release a full flow of water and close it again. It should now pump fully. Under some 
conditions the procedure might have to be repeated at each start up. 

STORAGE 

 

Make sure that the engine is completely cooled off before storage. 

 

Clean up oil and dust accumulation on rubber parts. 

 

Drain pump completely of all water. 

 

Cover the machine and store it in a dry place. 

 

For long-term storage of this petrol unit, remove fuel from the fuel tank. Also remove 
fuel remaining in the fuel line and chamber of the carburettor. To drain fuel from the 
chamber of the carburettor, remove the drain plug provided at the chamber and drain 
the fuel.

 

 

WARRANTY 

Consult the Crommelins Machinery Warranty Information leaflet, supplied with your new 
product, for details of your machinery warranty including consumer advice and 
information about accessing a service agent to repair your product. You can also visit our 
website at www.crommelins.com.au to find your local service agent who will be able to 
assist with all warranty claims.  

 

 

Summary of Contents for TFF150HP

Page 1: ...s use installation checking and maintenance We highly recommend that you retain this manual for ready reference regarding its proper handling Spare Parts Service Phone 1300 554 524 Freecall Fax 1800 6...

Page 2: ...t hand so that you can refer to it at anytime Due to constant efforts to improve our products certain procedures and specifications are subject to change without notice When ordering spare parts pleas...

Page 3: ...other poorly ventilated places as the exhaust fumes contain deadly poisonous carbon monoxide If the machine is unavoidably operated in such a place discharge the exhaust outside the room by a suitable...

Page 4: ...minute intervals N B Do not run the pump dry of water for extended periods as it will destroy the mechanical seal and void warranty HOW THE PUMP OPERATES Before starting the pump make sure the non ret...

Page 5: ...have to be repeated at each start up STORAGE Make sure that the engine is completely cooled off before storage Clean up oil and dust accumulation on rubber parts Drain pump completely of all water Co...

Page 6: ...360L min Volume max L hr 21 600L HR Max Suction lift m 8m Pump Type Aluminium Suction Type Self priming Impeller Single Axle Seal Material Ceramic carbon Engine Make Honda Engine Type GP160 Starting S...

Page 7: ...to engine manufacturers instruction manual Engine with low power 1 Throttle control lever not set to full throttle position 1 Set throttle control lever to full position Engine runs rough 1 Dirty air...

Page 8: ...ion Inlet 1 1 29 Set Screw 5 16 x 1 9 11 Priming Drain Plug Cap 2 32 Washer Inside Ratchet 3 8 x17 6 12 Gasket Discharge Bend 1 33 Nut UNF 3 8 6 13 Discharge Tee Outlet 1 1 34 Chain 3 14 Rubber Gasket...