54
5.3
C
HARGER FEATURES
Part Number
12V-40A
12V-60A
recommended battery bank*
300-500Ah
500-700Ah
Input
Voltage
from 90 to 265VAC single-phase automatic
Frequency
from 47 to 65Hz automatic
Input current consumption 230/115VAC
2.7/5.6A
4.4/8.7A
Power factor
1
Efficiency
Greater than 90%
Input fuses
T15A/250V
–
6.3 x 32 (F101)
Output
Number of battery banks
4 separate positive terminals : +BAT E, +BAT 1 et +BAT 2 +BAT3 (integrated Mosfet
splitter) / 1 -BAT negative terminals
Each bank can be used individually and delivers the rated current
Nominal current (+/-7%) / Rated Power
40A/570W
60A/855W
Charging curve
IU or IUoU through internal push-button, Bluetooth or CAN-Bus
(Boost, Absorption, Floating and Refresh)
Battery type
Lead sealed as factory setting - Gel, AGM, calcium lead, LiFePO4, DC power-supply
mode, etc.
Specific request on demand
Regulated and filtered output voltage
See 3.3.2
Peak to peak ripple and noise
< 2% (at rated conditions)
Automotive output fuse mounted in series in
minus pole -BAT
3 x 30A/32V
(F400, F401, F402)
4 x 30A/32V
(F400, F401, F402, F403)
Protections
- Against transient input overvoltage by varistor (out of warranty)
- Against output polarity inversions by fuse (replaceable automotive type)
- Against short-circuits and output overloads
- Against abnormal overheating by charger cut-off (automatic restart)
Options
Temperature probe
Output voltage compensation -18mV/°C
Communication
CANBUS & Bluetooth as standard
*Recommended battery capacity for lead type batteries, ratio C/10. Consult us for lithium batteries capacity
5.4
N
OMENCLATURE OF SHORE
-
POWER UNITS
AC part
Charger part
Part Number
Residual
Current
Device
Number of
outputs
16A circuits
breakers
10A circuits
breakers
Nominal
voltage
Nominal
current
Number of
outputs
UEYPOPL/12-40/3D
30mA / 16A
3
-
3
12 V
40A
4
UEYPOPL/12-40/4D
4
4
UEYPOPL/12-40/4D3
30mA / 32A
3
1
UEYPOPL/12-60/3D
30mA / 16A
3
-
3
60A
UEYPOPL/12-60/4D
4
4
UEYPOPL/12-60/4D3
30mA / 32A
3
1