Fermod Floor Guided Sliding Door Hardware Kits -
F2156 Installation Guide
www.crh.com.au
17
Step 12.
Install closing & opening side floor guides.
E = Door blade thickness (excluding gasket).
Example: If door blade thickness is 75mm
the measurement out from the frame will be
112mm.
R = Overlapping width.
Example: If the door overlaps the frame 50mm
on each side the following measurements would
apply.
Fig.a R - 46 = 4mm
Fig.b R + 1 = 51mm
Note: If fixing through floor tiles drill a 5mm pilot
hole before inserting the Masonary Anchors
other wise you may damage the tile.
Closing Side
Opening Side
Door Frame
Door Frame
Fig.a
Fig.b