Quick Start
The Crestron® TSW-560-LB is a room availability light bar for the Crestron TSW-560,
TSW-560P, and TSW-560-NC touch screens. When the light bar is installed onto a touch screen
as part of an enterprise room scheduling solution, the light bar illuminates to indicate the room’s
availability.
Check the Box
Item
Qty
TSW-560-LB-B or TSW-560-LB-W
1
Light Bar, 5 in., Black or Light Bar, 5 in., White
1
Screw, 04-40 x 1-1/2 in., Undercut Head, Phillips (P/N 2037906)
2
Screw, 04-40 x 3/8 in., Undercut Head, Phillips (P/N 2007173)
2
*
Refer to the TSW-560-LB-B and TSW-560-LB-W product page at
www.crestron.com
for a complete list of
color and texture variations.
Install the TSW-560-LB
Use the following procedures to install the TSW-560-LB as part of a new or existing TSW-560
installation.
NOTE:
For portrait touch screens (such as the TSW-560P), the TSW-560-LB may be installed
vertically using the same procedures required for a landscape touch screen installation.
Install the Light Bar Assembly
1.
If the TSW-560-LB is being added to an existing TSW-560 installation, pull the TSW-560
carefully out of its mounting bracket and disconnect the Ethernet cable.
NOTE:
If the TSW-560 is secured to the mounting bracket with a security latch, refer to
the removal procedure described in the TSW-560/TSW-760/TSW-1060 Quick Start
(Doc. 7926) at
2.
Use the two included 4-40 x 3/8 in. screws to attach the light bar assembly to the rear of
the TSW-560.
Light bar
assembly
Screw (2):
4-40 x 3/8 in.
USB connector
Touch screen
USB port
3.
Insert the assembly’s USB connector into the USB port on the rear of the touch screen.
Attach the Light Bar to the Mounting Bracket
1.
Loosen the two pan head 4-40 x 1-1/2 in. screws on the TSW-560 mounting bracket.
2.
If installed, remove the mounting bracket from the mounting surface as shown in the
following illustration.
Pull the top surface
up and out of the
mounting hole
TSW-560
mounting bracket
(side view)
Loosen both of the
pan head screws
3.
Separate the two halves of the mounting bracket by removing the two pan head 1-1/2 in.
screws. These screws are not used in this installation.
4.
Align the light bar in between the two halves of the mounting bracket as shown in the
illustration below.
5.
Attach the light bar to the front half of the mounting bracket, and then reconnect the two
halves of the mounting bracket.
NOTE:
Pull the flex circuit attached to the light bar through the opening in the mounting
bracket after the light bar is attached to the mounting bracket.
6.
Use the two included flat head 4-40 x 1-1/2 in. screws to secure the light bar to the
mounting bracket. Do not tighten the screws fully.
Screw (2):
4-40 x 1-1/2 in.
flat head
Flex circuit
TSW-560
mounting bracket
(front half)
Light bar
TSW-560
mounting bracket
(rear half)
NOTE:
Do not use the pan head 4-40 x 1/2 in. screws that come with the TSW-560
mounting bracket for the light bar installation. The flat head 4-40 x 1/2 in. screws that
come with the light bar must be used instead.
7.
Insert the mounting bracket, bottom side first, back into the mounting surface.
8.
Push the rear half of the mounting bracket back so that it is seated behind the mounting
surface completely.
9.
Tighten the two flat head 4-40 x 1-1/2 in. screws to secure the bracket to the mounting
surface.
Attach the Light Bar to the TS-5-MSMK
The light bar may also be attached to the TS-5-MSMK multisurface mounting kit for
applications where the touch screen will be mounted to a flat pane of glass or a similar
smooth surface (such as granite, marble, plaster, or smooth stone and masonry). For more
information on installing the TS-5-MSMK, refer to the TS-5-MSMK Quick Start (Doc. 8427) at
www.crestron.com/manuals
.
The following supplies (not included) are required for this installation: a level, a roll of tape, a
Phillips screwdriver, and a surface cleaning product that does not leave a residue.
Attach the TS-5-MSMK Mounting Plate to the Surface
1.
Clean and dry the mounting surface thoroughly.
2.
Use a level to tape a horizontal reference line to the surface to align with the lower edge of
the mounting plate.
3.
Remove the protective covering from the rear of the TS-5-MSMK mounting plate.
CAUTION:
The adhesive on the rear of the mounting plate is high-strength bond. Once the
adhesive comes in contact with a surface, it cannot be removed easily.
4.
Hold the mounting plate at a 45-degree angle to the surface, and then carefully align the
lower edge of the pad with the taped reference line. Do not allow the adhesive to come in
contact with the surface.
5.
Attach the mounting plate to the surface, starting with the bottom edge near the taped
reference line. Press the pad to the surface firmly to ensure proper adhesion and to
eliminate any trapped air bubbles.
Mounting plate
Glass surface
TSW-560-LB
Room Availability Light Bar for TSW-560, TSW-560P, and TSW-560-NC