Crestron TPMC-L-IMC User Manual Download Page 1

 Interface 

Module: 

TPMC-L-IMC

 

 

1.  As shown in the following diagram, connect the 

power wires from the TPMC-L-IMC to the rear of 
the touchpanel using the supplied connectors. 
Crestron recommends using two 60 foot runs (or 
less) of 14-gauge stranded wire between the 
touchpanel and the TPMC-L-IMC.  

Description 

The TPMC-L-IMC interface module is included with 
the TPMC-15-CH-L, TPMC-15-QM-L,  
TPMC-17-CH-L, and TPMC-17-QM-L touchpanels. 
The TPMC-L-IMC is used to deliver power from a 
power supply to a remotely located wall mount 
touchpanel. The TPMC-L-IMC converts the cable 
(used by the touchpanel’s included power supply) to 
two wires (see chart in following column), which 
allows a wall mount touchpanel to be installed up to 
60 feet from its power supply. The wire runs are 
terminated on the rear of the TPMC-15/17 wall 
mount touchpanel where they are converted to the 
cable-type required by the touchpanel. An LED 
indicates when power is supplied to the  
TPMC-L-IMC. The TPMC-L-IMC has a mounting 
flange to secure the unit to a mounting surface or 
the rear of a rack as shown in the following diagram. 
The TPMC-L-IMC should be installed near the power 
supply.  

Hardware Hookup 

PWR IN:

FROM EXTERNAL

POWER SUPPLY

TO TOUCHPANEL:

(60 ft MAX @ 14 GAUGE x2)

OBSERVE POLARITY

(

+

 to 

+

 and 

 to 

)

CABLE CONNECTED TO

PWR PORT ON BOTTOM OF

TOUCHPANEL

 

Physical Views of the TPMC-L-IMC 

2.53 in

(6.42 cm)

3.43 in

(8.70 cm)

1.05 in

(2.67 cm)

2.14 in

(5.42 cm)

1.97 in

(5.00 cm)

2.23 in

(5.66 cm)

 

Alternatively, a single wire can be run over a 
shorter distance. Smaller gauge wires can be 
used for shorter runs as well. Refer to the 
following table for wiring alternatives. 

Recommended Wire Lengths  
(Between TPMC-L-IMC and Touchpanel) 

WIRE 

GAUGE 

SINGLE WIRE 

(FEET) 

DOUBLE WIRE 

(FEET) 

14 AWG 

(2.5 mm

2

30 60 

16 AWG 

(1.5 mm

2

20 

40 

Installation: 

NOTE:

  If running a single wire, either PWR 

OUT connector can be used. Observe polarity 
when terminating wire (

+

 to 

+

 and 

 to 

). 

CAUTION:

 Ensure that the power is disconnected 

during installation. 

2.  Connect the power cable from the external 

power supply to the PWR IN port of the  
TPMC-L-IMC. The PWR LED will illuminate. 

CAUTION:

  Only the included Crestron power 

supply should be used. 

Crestron Electronics, Inc. 

Data Sheet – DOC. 6385 

15 Volvo Drive 

(2013189)  

Rockleigh, NJ 07647 

07.05 

Tel: 888.CRESTRON 

Specifications subject to change without notice. 

Fax: 201.767.7576  

www.crestron.com

 