background image

 
Crestron

 STX-1700CXPW  

Wall Mount 2-Way RF Wireless Touchpanel 
Operations Guide

 

Summary of Contents for STX-1700CXPW

Page 1: ...Crestron STX 1700CXPW Wall Mount 2 Way RF Wireless Touchpanel Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Software Requirements for the PC 18 Programming with the Crestron SystemBuilder 18 Programming with SIMPL Windows 19 Programming with VT Pro e 24 Optional Pushbuttons 24 Reserved Join Numbers 25 Uplo...

Page 4: ......

Page 5: ...a two way radio frequency RF compact color touchpanel that when used with the supplied DA 1700CW docking assembly and BB 1700CW back box is wall mounted and provides a user interface to a Crestron rem...

Page 6: ...version the STXI 1700CXPW Wi Fi Technology Wi Fi wireless fidelity is the common term for high frequency wireless local area network WLAN technology that is gaining acceptance as an alternative to a...

Page 7: ...of Channels 1 6 and 11 is safest since that choice produces no overlap As described earlier Crestron RF devices make use of bands that define frequency ranges within the same spectrum For example Ban...

Page 8: ...t RF Band Band 0 USA Original Ten frequency bands ranges available for selection Default Timeouts 10 minutes for standby 30 minutes for power down Signal Join Maximums 4000 digital 1024 analog 127 ser...

Page 9: ...ies control systems 6 CNX update files are required for either CNMSX AV PRO or CNRACKX DP Filenames for CNX update files have a UPZ extension and are in one EXE or zipped UPZ file To avoid program pro...

Page 10: ...1700CXPW continued The underside of the unit contains the battery compartment that holds one ST BTPN Contacts for the DA 1700CW are through the ST BTPN Four rubber feet on the underside of the unit ar...

Page 11: ...s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can determined by turning the equi...

Page 12: ...ntacts of the ST BTPN If the ST BTPN is not installed the DA 1700CW will not electrically undock the touchpanel it would have to be manually undocked refer to Manually Undocking of Touchpanel on page...

Page 13: ...ram defines the method i e touchpanel button of unlatching Electrical Undocking of Touchpanel 1 Via the touchpanel and or control system program unlatch the touchpanel 2 Pull the upper edge of the tou...

Page 14: ...a long reach screwdriver into the access hole at a downward angle approximately 10o until the tip of the screwdriver contacts the manual unlatch tab Insert Screwdriver 3 As shown below lower the handl...

Page 15: ...within a Cresnet system Cresnet identity Net ID for instances when the touchpanel is wired to the Cresnet system and RF ID for those instances when the touchpanel communicates with the Cresnet system...

Page 16: ...es the channel ID of the TPS RFGWX There are 16 possible RF channels ranging from 0 to F hexadecimal number Having multiple channels available allows for multiple gateways and therefore many multiple...

Page 17: ...left corner Touch the cross hair to initiate calibration Another message Touch Upper Right appears with a cross hair in the correct corner Touch the cross hair A final message Touch Lower Right appea...

Page 18: ...to display the CRESNET INTERFACE MENU or the RF SETUP screen respectively Use these screens to set the Cresnet network identity CRESNET ID and the RF ID numbers Refer to Identity Codes on page 11 Cre...

Page 19: ...d gateway must be set to the same band in order to communicate Refer to the latest revision of the TPS RFGWX Operation Guide Doc 5847 for more information on setting up the band for the RF gateway 1 2...

Page 20: ...when the touchpanel display is dark the user may have to press the pushbutton twice with a minimum two second interval between presses This method is preferred because when a panel display is inactive...

Page 21: ...that the purpose of this timeout is to maximize battery life Standby timeout still functions Press Return to save the settings and return to the SETUP MENU DIAGNOSTICS Menu DIAGNOSTICS MENU The Diagno...

Page 22: ...etails regarding VT Pro e Earliest Version Software Requirements for the PC NOTE Crestron recommends that you use the latest software to take advantage of the most recently released features The lates...

Page 23: ...wireless RF configuration issues before running the program in wireless mode SIMPL Windows is Crestron s software for programming Crestron control systems It provides a well designed graphical environ...

Page 24: ...dentical they are not interchangeable In Configuration Manager drag the STX 1700CXP Cresnet icon from the Touchpanels Cresnet folder of the Device Library and drop it in the upper pane of the System V...

Page 25: ...D refer to RF Setup shown on page 14 NOTE SIMPL Windows automatically changes NET ID values of a device added to a program if a duplicate device or a device with the same default NET ID already exists...

Page 26: ...en signal The signal type is displayed on the Status Bar when the signal is highlighted For additional information refer to Doc 6120 Crestron SIMPL Windows Symbol Guide It may be downloaded from the C...

Page 27: ...s The programmer selects the signal types by clicking on the appropriate button at the top of the Symbol Detail view when programming the panel The following tables list functional descriptions for to...

Page 28: ...ect is uploaded to the touchpanel s flash PROM The touchpanel uses the project until another is uploaded from the PC The PC may be disconnected from the control processor except when uploading a proje...

Page 29: ...O 17303 Keyclick Off I O 17304 Key Click Volume Up I 17305 Key Click Volume Down I 17322 Key Click Short Short Default I 17323 Key Click Medium Medium I 17324 Key Click Long Long I 17509 Out of Range...

Page 30: ...are change system and network parameters and communicate with network device consoles and touchpanels among many other tasks Viewport can also function as a terminal emulator for generic file transfer...

Page 31: ...control system in use has a 4 pin network connector rather than a modular RJ 11 type NET connector use an ST CBL interface cable sold separately NOTE To make a cable for either configuration refer to...

Page 32: ...L to the touchpanel 3 Attach the network connector end of the ST CBL to the connector labeled NET on the control system 4 Attach the appropriate Crestron external power pack to the touchpanel and plug...

Page 33: ...s is Eight the stop bits is One XON XOFF is not selected and RTS CTS is selected Click the OK button to save the settings and close the window NOTE If problems occur when transferring any Cresnet file...

Page 34: ...mmunication Settings which begins on page 26 has been performed 2 As shown below select File Transfer Send Touchpanel alternatively depress Alt T from the Viewport menu Select Send Touchpanel 3 As sho...

Page 35: ...ant that the unit contains the latest firmware Please check the Crestron website for the latest version of firmware Not every product has a firmware upgrade but as Crestron improves functions adds new...

Page 36: ...Wireless Touchpanel STX 1700CXPW Operations Guide DOC 6249A Select Network ID Window 4 As shown below select the firmware CSF file and click Open The transfer will complete automatically Select CSF Fi...

Page 37: ...rify communication Touchpanel does not report as Cresnet device to control system when mounted in DA 1700CW Touchpanel not making connection Check that rubber feet on bottom of touchpanel are mounted...

Page 38: ...not set to match the RF ID assigned in the control system program Verify that RF IDs match Refer to Select Interface on page 14 for details and RF ID parameters assigned in the program Sig LED on TPS...

Page 39: ...Crestron worldwide offices You can also log onto the online help section of the Crestron website to ask questions about Crestron products First time users will need to establish a user account to ful...

Page 40: ...tem to see that it is using only channels that are not being used by the STX 1700CXPW touchpanel If necessary change the touchpanel s band setting to avoid interference Refer to ADDITIONAL RF SETUP on...

Page 41: ...Touchpanel STX 1700CXPW 37 NOTE RF propagation is best from the sides of the antenna Horizontal Orientation Top of gateway Antenna Building Vertical Orientation TPS RFGWX Antenna Front of gateway Bui...

Page 42: ...the base Holding the bezel to the base return the unit to its normal position and lift the bezel from the base 3 Assemble the supplied membrane switches to the pushbutton sets Notice that the pushbutt...

Page 43: ...d including but not limited to using the Software a either directly or through commands data or instructions from or to another computer b for local campus or wide area network internet or web hosting...

Page 44: ...rm substantially in accordance with the published specifications for a period of ninety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own li...

Page 45: ...en display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON...

Page 46: ...Wall Mount 2 Way RF Wireless Touchpanel Crestron STX 1700CXPW 42 Wall Mount 2 Way RF Wireless Touchpanel STX 1700CXPW Operations Guide DOC 6249A This page intentionally left blank...

Page 47: ...Crestron STX 1700CXPW Wall Mount 2 Way RF Wireless Touchpanel Operations Guide DOC 6249 Wall Mount 2 Way RF Wireless Touchpanel STX 1700CXP 43 This page intentionally left blank...

Page 48: ...Crestron Electronics Inc Operations Guide DOC 6249A 15 Volvo Drive Rockleigh NJ 07647 12 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: