 Install the SSW

The SSW installs over a standard 1-gang U.S. electrical box. Use the following procedure to install 
the SSW:

1. Once all cable connections have been made, use the two included 6-32 x 5/16" screws and 

a Phillips screwdriver (not included) to attach the SSW rear assembly to the electrical box, as 
shown in the following illustration.

NOTE

:  For retrofit installations, the SSW  can be installed over a 1-gang plaster ring using the 

same installation method described above.

SSW-100/SSW-102 

Room Availability Hallway Sign, Wall Mount

DO

 Connect the SSW

The Crestron

®

 SSW can be powered and controlled using one of the following connection methods:

 

USB:

 Use the included USB cable to connect the SSW to a Crestron TSW-560, TSW-760, or 

TSW-1060 touch screen. Connect the cable’s USB A connector to the touch screen and the 
micro USB connector to the SSW rear assembly. Although the touch screen can be powered 
using standard PoE (power over Ethernet), it must be powered using PoE+ to supply power to 
the SSW over USB. Out-of-the-box functionality is established via the scheduling SmartObject

® 

program with no programming required.

 

Cresnet

®

 Network:

 Use any standard Cresnet cable (not included) to connect the SSW to a 

Crestron control system or DMPS device. The SSW is powered and controlled over Cresnet via 
programming in SIMPL Windows or Crestron Studio

®

 software.

NOTE

:  The 

CNET ID

 button on the front of the assembly is used to identify the device on 

the network using the Network Device Tree View in Crestron Toolbox™ software. For more 
information, refer to the embedded Crestron Toolbox help file. 

NOTE

:  All cable connections must be made prior to installing the SSW.

NOTE

:  Use Crestron power supplies for Crestron equipment. 

DO

 Check the Box

QTY PRODUCT

COLOR

PART NUM.

1

Bezel, Wall Sign

Clear

4525866

1

Cable, USB 2.0, A - micro B, 6’ (1.83 m)

2038114

2

Screw, 4-40 x 1/2", SEMS, Pan Head, Phillips

2011592

2

Screw, 6-32 x 5/16", Pan Head, Phillips

2007221

1

Sign, 8.0" x 5.25" x 0.5"

4525763