background image

Quick Start

The Crestron® SSC-ACR series is a replacement for the acrylic sign 

face that is used with the Crestron SSC room availability hallway 

sign. 
For simplicity within this guide, the term “acrylic face” is used to refer 

to all models in the series, except where otherwise noted. 

Check the Box

Item

Qty

SSC-ACR-100, SSC-ACR-100-EL, SSC-ACR-102,  

or SSC-ACR-102-EL

 

1

Refer to the SSC-ACR product page at 

www.crestron.com

 for a complete list of color 

and texture variations.

Install the 

Replacement Acrylic Face

An installed SSC (Room Availability Hallway Sign) consists of a bezel, 

acrylic face, and the SSC assembly. The purpose of the following 

sections is to disassemble the SSC, replace the acrylic face, and 

reassemble. 

Disassemble the SSC

Remove the Bezel from the SSC Assembly

SSC 

assembly

Bezel

Acrylic 

face

1. 

Remove the bezel from the SSC assembly by gently pulling it 

away from the installed sign to break the magnetic hold, then 

sliding it down and across the acrylic face. Retain the bezel.

 

Locate Latch Release Tabs on SSC Assembly (Angled View)

 

Latch release 

tab

Latch release 

tab

NOTE: 

Each end of the SSC assembly has a latch release tab 

that secures the acrylic face to the assembly. 

 

Remove the Acrylic Face from the SSC Assembly

 

Press one latch 

release tab.

Rotate around 

unpressed latch 

release tab.

SSC

assembly

Acrylic

face

2. 

Use both hands to complete the following items simultaneously 

and remove the acrylic face from the SSC assembly. 

• 

Press the release tab of one latch upward.

• 

Hold the acrylic face with the other hand and rotate it 

around the unpressed latch until it slips away from the 

assembly. 

Reassemble the SSC

NOTES: 

• 

Ensure that the SSC assembly is properly mounted before 

attaching the replacement acrylic face. For more information on 

installing the SSC, refer to the SSC Series DO Guide (Doc. 7967) 

at 

www.crestron.com/manuals

• 

Leave the plastic film on the acrylic face during reassembly to 

protect it.

Attach Replacement Acrylic Face

CNET ID 

button

Machined 

recess in 

acrylic face

SSC 

assembly

1. 

Align the replacement acrylic face with the SSC assembly so 

that the side of the face with the machined recesses is facing 

away from the side of the assembly with the CNET ID button.  

NOTE: 

Install the acrylic face evenly into the SSC assembly so 

that the grooves in the top of the face engage both latches at 

the same time. The face does not easily install into the assembly 

when inserted at an angle. 

2. 

Push the acrylic face evenly up against both of the latch release 

tabs. As pressure is applied, the latches click to securely engage 

the face to the assembly.

3. 

Remove the plastic film from the acrylic face. 

SSC-ACR Series

Replacement Acrylic Sign Face for the Room Availability Hallway Sign (SSC Series)