Crestron
RoomView
Software
Crestron Programming
Control System Configuration
Each control system that is monitored by RoomView must have an Ethernet card
and IP address.
In addition, the SIMPL Windows program must include an RoomView Interface
to allow communication with RoomView. The RoomView installation package
includes a sample SIMPL Windows program called RoomView.smw, located in
the \Demo folder. The sample program shows how the Interface symbol detail
should be defined (this is explained later in this section).
NOTE:
The join numbers (with the exception of the analog, digital and serial
joins for new room attributes) in the Interface are fixed and must be the same for
every control system program.
If you do not use the sample program you can bring the Interface into an
existing program by dragging it to
Detail View
from the Ethernet Modules
(Generic) folder of the
Device Library
.
Both the IP address of the control system and the IP ID of the RoomView
Interface symbol must match the
room settings
you specify in RoomView. To
set the IP ID of the RoomView Interface, double-click the symbol in
System
Views
and click the
IP Net Address
tab. Select the IP ID from the drop-down
list, and set the IP address to localhost: 127.0.0.1—the loopback address of the
control system.
Reference Guide – Doc. 6133
Crestron RoomView
•
47