Crestron DM-PSU-ULTRA-MIDSPAN Installation Manual Download Page 1

DM-PSU-ULTRA-MIDSPAN

DigitalMedia™ Ultra Midspan PoDM++ Injector
Installation Guide

Connection to DMPS3-4K-150-C and DM-RMC-4K-SCALER-DSP

Description

The DM-PSU-ULTRA-MIDSPAN provides two PoDM++ power sourcing equipment (PSE) 
ports designed to power DM 8G+

®

 PoDM powered devices (PDs). Each PoDM++ port of 

the DM-PSU-ULTRA-MIDSPAN can supply up to 45 watts of power to a PoDM++, 
PoDM+, or PoDM powered device. (Due to the inherent power loss over CATx cable, a 
maximum of 40 watts is delivered to the powered device.) 
The DM-PSU-ULTRA-MIDSPAN can simultaneously power a DM 8G+ transmitter and 
receiver in a standalone configuration while passing data between the two devices. 
The DM-PSU-ULTRA-MIDSPAN can also power a touch screen that has a DM 8G+ input 
(for example, a TS-1542-C). 

2

3

4

DM-RMC-4K-SCALER-C-DSP,

side panel

DMPS3-4K-150-C, rear panel

DM-PSU-ULTRA-MIDSPAN

NOTE:

  The DM-PSU-ULTRA-MIDSPAN supplies power to a connected device only if 

the device requests power. As a result, the DM-PSU-ULTRA-MIDSPAN can be 
connected to the PSE port of a device that does not require power from the 
DM-PSU-ULTRA-MIDSPAN (for example, a DMPS3-4K-150-C).

DM-PSU-ULTRA-MIDSPAN

DM-TX-4K-302-C, 

side panel

DM-RMC-4K-SCALER-C-DSP,

side panel

Connection to DM-TX-4K-302-C Transmitter and DM-RMC-4K-SCALER-C-DSP Receiver

NOTE:

  The DM-PSU-ULTRA-MIDSPAN is compatible with HDBaseT Alliance 

specifications and can be used to supply up to 30 watts of power to IEEE 802.3at 
compliant HDBaseT

®

 devices. (Due to the inherent power loss over CATx cable, a 

maximum of 25.5 watts is delivered to the HDBaseT PoE+ or PoE powered device.)

Additional Resources

Visit the product page on the Crestron website (www.crestron.com) 
for additional information and the latest firmware updates. Use a QR 
reader application on your mobile device to scan the QR image.

Mounting

The DM-PSU-ULTRA-MIDSPAN can be mounted into a rack, onto a rack rail, or under a 
table:

 •  To mount the DM-PSU-ULTRA-MIDSPAN into a rack, use the Crestron

®

 ST-RMK 

Rack Mount Kit (sold separately). 

 •  To mount the DM-PSU-ULTRA-MIDSPAN onto a rack rail, use two mounting screws 

(not included).

 •  To mount the DM-PSU-ULTRA-MIDSPAN to the underside of a table, use four 

#12 x 5/8-inch 

mounting screws (not included).

Hardware Hookup

Connect the DM-PSU-ULTRA-MIDSPAN as required for the application. 

Hardware Hookup

From ac power

source

To PoDM++

powered device

1, 2

Refer to the following illustrations for sample connection diagrams.

The PoDM++ PSE ports are also compatible with PoDM+, PoDM, HDBaseT PoE+, and HDBaseT PoE 

  powered devices.

Any wiring that is connected to a PoDM++ PSE port is for intrabuilding use only and should not be connected 

 to a line that runs outside of the building in which the PSE is located.

To PoDM++

powered device

1, 2