  1.  Place the top of the DIN-AO8’s rail mount over the top of the DIN rail.
  2.  Tilt the bottom of the DIN-AO8 toward the DIN rail until it snaps into place.

NOTE

:  When mounting DIN rail products, it may be necessary to use a flat-head 

screwdriver to pull the DIN rail release tab while snapping the device onto the DIN rail.

NOTE

:  Certain third-party DIN cabinets provide space for an informational label 

between each DIN rail row. Crestron’s Engraver software (version 4.0 or later) can 
generate appropriate labels for all Crestron DIN rail products.

Description

The Crestron

®

 DIN-AO8 is a DIN rail-mounted automation control module that provides 

eight analog output ports for interfacing with third-party lighting and heating and cooling 
systems.

Installation

WARNING

:  To avoid fire, shock, or death, turn off the power at the circuit breaker or 

fuse and test that the power is off before wiring! 

NOTES

:  Observe the following points:

  •  This product must be installed and used in accordance with appropriate electrical 

codes and regulations.

  •  This product must be installed by a qualified electrician.

Additional Resources

Visit the product page on the Crestron website (www.crestron.com) 
for additional information and the latest firmware updates. Use a QR 
reader application on your mobile device to scan the QR image.

Hardware Hookup

Make the necessary connections. Apply power after all connections have been made.

WARNING

:  Prior to connecting the device, turn off power at the circuit breaker. Failure 

to do so may result in serious personal injury or damage to the device. Restore power 
after all connections have been made.

CAUTION

:  Connecting this device to the wrong type of load or short-circuiting the load 

can cause severe product damage. Each load should be tested to identify a short-circuit 
condition prior to wiring the load to the module.

NOTE

:  Use copper wire only. 

NOTE

:  Each switch leg of the DIN-AO8 may be fed from a separate circuit breaker.

When making OUTPUTS, NET, and OVERRIDE connections, strip the ends of the wires 
approximately 7/16 in (11 mm). Use care to avoid nicking the conductors. Tighten the 
connector to 5 in-lb (0.5 to 0.6 N-m). The wire gauge should be 14 to 26 AWG.
When making power connections to the DIN-AO8, use a Crestron power supply.

Hardware Connections for the DIN-AO8

OUTPUTS:

To Devices with 

Analog Inputs

NET:

To Control System and 

Other Cresnet Devices

OVERRIDE:

From Device Providing 

Override Signal and to Other 

Devices Receiving Override 

Signal

DIN-AO8

DIN Rail (Not 

Supplied)

DIN Rail 
Release

Top

NOTE

:  To remove the DIN-AO8 from the DIN rail, use a small, flat object (i.e., a 

flat-head screwdriver) to pull the DIN rail release and tilt the bottom of the DIN-AO8 
away from the DIN rail.