Page 1: ...DIN 1TSTAT8 8 Zone Radiant Heat Thermostat DIN Rail Mount Product Manual Crestron Electronics Inc ...

Page 2: ..._ agreement The product warranty can be found at www crestron com warranty The specific patents that cover Crestron products are listed online at www crestron com legal patents Certain Crestron products contain open source software For specific information please visit www crestron com opensource Crestron the Crestron logo and Cresnet are either trademarks or registered trademarks of Crestron Elec...

Page 3: ...ain Valve connections 1 8 MAIN 13 Temperature Sensor Connections TEMP SENSE 14 Cresnet Connections NET 14 Verify System Operation 15 Operation 16 Bootup 16 Main Valve Delay 16 1 8 Buttons and LEDs 16 MAIN Button and LED 16 Temperature Sensors 16 Failsafe Mode 17 Troubleshooting 18 Resources 19 Crestron Support and Training 19 Programmer and Developer Resources 19 Product Certificates 19 Product Ma...

Page 4: ...iv Contents Product Manual Doc 9368A ...

Page 5: ...y closed contacts and is rated for 1 2 HP at 240VAC 50 60 Hz A Crestron control system connection allows temperature adjustments on each zone from virtually anywhere by using a Crestron touch screen handheld remote mobile app or computer The DIN 1TSTAT8 requires a Crestron control system to function The heating setpoints for each zone are set by the user through the control system and then stored ...

Page 6: ...nnection of a control system and during runtime if the normal setpoint stored in memory gets corrupted reverts to the normal setpoint once a value is received from the control system Main Valve Delay 5 minutes factory setting adjustable from 0 to 5 minutes Communications Cresnet Cresnet secondary mode Connections 1 8 8 sets of 3 Captive screw terminals Comprises 8 zone valve control outputs with i...

Page 7: ...1 Red LED and 1 pushbutton button toggles the main output on and off when held 10 seconds LED indicates the main output is on flashes with heat call steady without heat call SETUP 1 Recessed pushbutton and 1 red LED for Cresnet TSID touch settable ID PWR 1 Green LED indicates device is powered via Cresnet NET 1 Yellow LED indicates Cresnet communication with the control system RESET 1 Recessed pus...

Page 8: ...T8 Product Manual Doc 9368A Weight 0 5 kg 1 08 lb Compliance Regulatory Model DIN 1TSTAT8 CE IC FCC Part 15 Class B digital device To search for product certificates refer to support crestron com app certificates ...

Page 9: ...Product Manual Doc 9368A DIN 1TSTAT8 9 Dimension Drawings ...

Page 10: ...10 DIN 1TSTAT8 Product Manual Doc 9368A Installation This section provides the following information Install the DIN 1TSTAT8 Wire the DIN 1TSTAT8 Verify System Operation ...

Page 11: ... Crestron s Engraver software version 4 0 or later can generate appropriate labels for all Crestron DIN rail products Mount the DIN 1TSTAT8 to the DIN rail 1 Hang the DIN 1TSTAT8 on the top of the DIN rail 2 Press the bottom toward the DIN rail and snap it into place Remove the DIN 1TSTAT8 from the DIN rail 1 Turn off power to the thermostat and the heating system 2 Remove all connections from the...

Page 12: ...12 DIN 1TSTAT8 Product Manual Doc 9368A Wire the DIN 1TSTAT8 Make the following connections to the thermostat ...

Page 13: ...l valve to the MAIN terminal on the thermostat Do not connect a zone valve to the MAIN port l For 2 wire normally open valves connect the NO terminal on the thermostat to the OPEN terminal on the valve l For 3 wire valves connect the NO terminal on the thermostat to the OPEN terminal on the valve and then connect the NC terminal on the thermostat to the CLOSE terminal on the valve For zone valve s...

Page 14: ...ng the temperature sensors o Use a separate run of wire for each sensor If using multi conductor cable use only one pair per cable o Do not run temperature sensor lines parallel to any other wiring Cross cables at right angles o In situations where ordinary two conductor thermostat wire 18 to 20 gauge has been installed it may be used for runs up to 30 m 100 ft This is not a preferred method of in...

Page 15: ...mode on the associated zone 2 Verify that the zone valve operates as expected The DIN 1TSTAT8 performs a 5 minute heat call on that zone If the valve is programmed to have a time delay the delay is initiated and added to the test call for heat The zone LED flashes for the duration of Test mode The zone valve main valve and DIN 1TSTAT8 return to their previous states when Test mode has been complet...

Page 16: ...l Extinguishes when heat is disabled MAIN Button and LED Press and hold the MAIN button for 10 seconds to switch the main valve on and off The MAIN LED l Flashes during a heat call for one or more zone valves l Lights when heat is on for one or more zone valves l Extinguishes when all zone valves are off Temperature Sensors The temperature sensors operate as follows l The temperature sensor reads ...

Page 17: ...et to the failsafe setpoint Establish the failsafe setpoint in the control system program The failsafe setpoint can range from 5 ºC 41 ºF to 20 ºC 68 ºF the default failsafe setpoint is 20 ºC 68 ºF Temperate zones can use a lower failsafe setpoint and cold climates may use a higher value The thermostat exits Failsafe mode after it reestablishes communication with the control system or if the store...

Page 18: ...s required please contact Crestron True Blue Support Trouble Possible Cause s Corrective Action The thermostat is not receiving a signal There is an improper connection between the sensor and the thermostat Check the connection between the sensor and thermostat An incomplete open circuit exists in wiring Check the connection between the sensor and thermostat ...

Page 19: ...ue Blue Support l Crestron Resource Library l Crestron Online Help OLH l Crestron Training Institute CTI Portal Programmer and Developer Resources l help crestron com Provides help files for Crestron programming tools such as SIMPL SIMPL and Crestron Toolbox software l developer crestron com Provides developer documentation for Crestron APIs SDKs and other development tools Product Certificates To...

Page 20: ...This page is intentionally left blank Product Manual Doc 9368A DIN 1TSTAT8 20 ...

Page 21: ...Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 Tel 888 CRESTRON Fax 201 767 7656 www crestron com Product Manual Doc 9368A 12 01 22 Specifications subject to change without notice ...