Crestron DIN-1DIMU4 Operations & Installation Manual Download Page 35

Crestron 

DIN-1DIMU4

 

DIN Rail Universal Dimmer

 

Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange or service without prior authorization 

from CRESTRON. To obtain warranty service for CRESTRON products, contact an 
authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory 
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying 
the nature of the problem, name and phone number of contact person, RMA number and 
return address. 

2.  Products may be returned for credit, exchange or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped freight 
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with 
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect 
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its 
sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any 
products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by CRESTRON, 

shipping by standard ground carrier. In the event repairs are found to be non-warranty, return 
freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials 
and workmanship under normal use for a period of three (3) years from the date of purchase from 
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical 
parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and 
overlay components are covered for 90 days; batteries and incandescent lamps are not covered.  

This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON 
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if 
any. 

CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended or if it has been subjected to misuse, accidental 
damage, modification or improper installation procedures. Furthermore, this warranty does not cover any 
product that has had the serial number altered, defaced or removed. 

This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall 
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages 
inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a 
third party or made by the purchaser for a third party. 

CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or 
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the 
unexpired portion of the warranty. 

Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or 
implied, nor authorizes any other party to offer any warranty, including any implied warranties of 
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are 
limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. 

 

 
 

Operations & Installation Guide – DOC. 6668D  DIN Rail Universal Dimmer: DIN-1DIMU4  

  31 

Summary of Contents for DIN-1DIMU4

Page 1: ...Crestron DIN 1DIMU4 DINRailUniversalDimmer Operations Installation Guide...

Page 2: ...nd can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interf...

Page 3: ...nts for the PC 17 Programming with Crestron SystemBuilder 18 Programming with D3 Pro 18 Programming with SIMPL Windows 18 Example Program 20 Uploading and Upgrading 21 Establishing Communication 21 Pr...

Page 4: ......

Page 5: ...dimmable fluorescent and non dimmable lighting loads up to 5 Amps per channel 10 Amps total Features and Functions Four channels of forward or reverse phase dimming Auto load detection 120 to 240 Volt...

Page 6: ...t Protection Built in over current protection OCP prevents failure of the DIN 1DIMU4 caused by excessive loading or improper wiring of the outputs Master Air Gap Relay When all four channels are turne...

Page 7: ...mation Processor or other Crestron 2 Series control system via the Cresnet control network A pair of Cresnet ports is provided on the DIN 1DIMU4 allowing for easy daisy chaining of several DIN Rail Se...

Page 8: ...AC 2300 Watts 230 Volts AC 2400 Watts 240 Volts AC Load Types Forward phase leading edge or reverse phase trailing edge electronic low voltage Incandescent Neon cold cathode Magnetic low voltage Dimm...

Page 9: ...Refer to the NOTE following these footnotes 2 Crestron 2 Series control systems include the AV2 and PRO2 Consult the latest Crestron Product Catalog for a complete list of 2 Series control systems 3 U...

Page 10: ...n the connections controls and indicators available on your DIN 1DIMU4 DIN 1DIMU4 Physical View DIN 1DIMU4 Overall Dimensions Front View 2 3 4 1 95 mm 3 71 in 216 mm 8 49 in 5 6 13 3 7 8 9 10 11 12 14...

Page 11: ...NET ID DISPLAY and CONTROL 2 7 segment green LED digits and 2 miniature pushbuttons for setting Cresnet ID Digits also display output levels and protection error codes 2 SETUP LED and Button 1 Red LED...

Page 12: ...ED normally indicates AC line power is connected to either LIVE terminal blinks when only powered by Cresnet 5 NET LED 1 Yellow LED indicates communication with the control processor 6 RESET 1 Recesse...

Page 13: ...de Select 1 4 4 Recessed miniature push buttons used to select each channel s operating mode For more information refer to Operation which starts on page 23 12 LOADS 1 4 LEDs and Buttons 4 Red LEDs an...

Page 14: ...inimum Closure Rating 10mA per module at 24 Volts 15 LIVE 2 Captive screw terminals2 brown Line power input 16 NEUTRAL 5 Captive screw terminals2 blue 17 DIMMED LIVE 1 4 4 Captive screw terminals2 red...

Page 15: ...For more details refer to Check Network Wiring which starts on page 28 Identity Code The Net ID of the DIN 1DIMU4 has been factory set to 86 The Net IDs of multiple DIN 1DIMU4 devices in the same syst...

Page 16: ...rk over the digits that correspond to the assigned Net ID NET ID Label 3C Shown When setting the Net ID consider the following The Net ID of each unit must match an ID code specified in the SIMPL Wind...

Page 17: ...release tab while snapping the device onto the DIN rail 3 Tilt the top of the DIN 1DIMU4 toward the DIN rail until it is secure on the top edge of the rail Push the DIN rail release upward to lock the...

Page 18: ...power supplies for Crestron equipment Hardware Connections for the DIN 1DIMU4 NET To Control System and Other Cresnet Devices NEUTRAL Neutral Connection from AC Power Line DIMMED LIVE 1 4 Dimmer Chan...

Page 19: ...ct damage Each load should be tested to identify a short circuit condition prior to wiring the load to the module NOTE Install in accordance with all local and national electric codes NOTE High voltag...

Page 20: ...the unit is properly grounded by connecting the chassis ground lug to an earth ground building steel NOTE To prevent overheating do not operate this product in an area that exceeds the environmental...

Page 21: ...mBuilder D3 Pro or SIMPL Windows to create a program to control the DIN 1DIMU4 Customers whose focus is on lighting systems may prefer to use the D3 Pro software since it is designed especially for cr...

Page 22: ...m each providing a moveable toolbox of devices such as interfaces fixtures and control modules You can add a device to your system simply by selecting it from one of the toolboxes and dragging it to a...

Page 23: ...the device in the appropriate slot with a default Net ID as shown in the following illustration C2Net Device Slot 5 2 If additional DIN 1DIMU4 devices are to be added repeat step 1 for each device Eac...

Page 24: ...Identity Code on page 11 Program Manager Program Manager is the view where programmers program a Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking on...

Page 25: ...ils There is a single method of communication indirect communication Indirect Communication Cresnet Control System PC Running Crestron Toolbox or USB Serial LAN DIN 1DIMU4 DIN 1DIMU4 connects to contr...

Page 26: ...can be uploaded to the control system using SIMPL Windows or Crestron Toolbox Firmware Check the Crestron Web site to find the latest firmware New users may be required to register to obtain access to...

Page 27: ...ID display as a percentage 01 99 for two seconds after the button is released NOTE The control system program may change the settings if the Override mode is not enabled Override Mode The Override mo...

Page 28: ...ed The dimmer s default operating mode is AUTO an appropriate mode for various types of dimming operation The output mode of the dimmer only needs to be changed when the connected device is not dimmab...

Page 29: ...nder module sold separately NON DIM AUTO REV FWD AUTO Channel operates as a dimmer and uses the built in auto load detection to determine the most suitable dimming technology The AUTO LED will illumin...

Page 30: ...uit breaker is not tripped Device is not receiving power from a Crestron power source Use a Crestron power source Verify connections Device is not receiving sufficient power Use the Crestron Power Cal...

Page 31: ...times per second The channel has overheated and shut down to protect itself Reduce loading on the channel Reduce loading on the module Improve enclosure ventilation to reduce ambient temperature Unit...

Page 32: ...n warranty CAUTION Provide sufficient power to the system Insufficient power can lead to unpredictable results or damage to the equipment Use the Crestron Power Calculator to help calculate how much p...

Page 33: ...r and the other twisted pair is the Y conductor and the Z conductor Strip and Tin Wire When daisy chaining Cresnet units strip the ends of the wires carefully to avoid nicking the conductors Twist tog...

Page 34: ...888 273 7876 You can also log onto the online help section of the Crestron Web site www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user...

Page 35: ...t heads and power supplies are covered for a period of one 1 year touchscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty exte...

Page 36: ...on Electronics Inc Operations Installation Guide DOC 6668D 15 Volvo Drive Rockleigh NJ 07647 2020750 Tel 888 CRESTRON 11 10 Fax 201 767 7576 Specifications subject to www crestron com change without n...

Reviews: