Observe the following when connecting the CP3-R:
•
Use Crestron power supplies for Crestron equipment.
•
The CP3-R may be powered with the included 24 Vdc power supply or with the NET 4-pin terminal block connector.
•
The included cables may not be extended.
•
Connect the chassis ground lug to a known earth ground circuit to ensure the CP3-R is properly grounded (for example, building steel).
•
Apply power after all connections have been made.
DO
Download the Crestron Pyng
®
App
The Crestron Pyng
®
app may be downloaded onto an Apple
®
iPad
®
device from the iTunes
®
application App Store
®
online store.
NOTES:
•
An iTunes account is required to download the Crestron Pyng app. Refer to
https://support.apple.com/kb/HT2731
for help with setting up an iTunes
account.
•
For a comprehensive list of iOS
®
hardware and software versions that are compatible with the Crestron Pyng app, refer to OLH article 5655 at
https://support.crestron.com/app/answers/detail/a_id/5655
.
To download the Crestron Pyng app:
1. Tap the
App Store
icon on the iPad device home screen.
2. Tap the search field, and enter the search term “Crestron Pyng.”
3. Tap
Search
.
4. Tap the
Crestron Pyng
app icon .
5. Follow the prompts to download the app to the device.
DO
Configure the System
Once the Crestron Pyng app is downloaded and installed, system setup takes place entirely through the app.
Tap the Crestron Pyng app icon on the iPad device home screen. The Crestron Pyng app connects to the CP3-R automatically, and a splash screen is
displayed.
NOTE:
Ensure that the iPad device and the CP3-R are placed on the same subnet prior to configuration.
For more information on setting up and configuring the Crestron Pyng system, refer to the Crestron Pyng Application for CP3-R Product Manual (Doc. 8356)
at
.
CP3-R
3-Series
®
Control Processor for Crestron Pyng
®
Application
DO
Install the Device
The Crestron
®
CP3-R may be mounted into a rack or placed onto a flat surface.
Mount into a Rack
The CP3-R occupies 1U of rack space. Use a #1 Phillips screwdriver to remove the required screws from the CP3-R assembly (shown in the illustration
below), and then attach the two included rack ears with the removed screws. Mount the CP3-R into the rack with four mounting screws (not included).
Place onto a Flat Surface
When the CP3-R is placed onto a flat surface or stacked with other equipment, attach the four included feet near the corners on the underside of the CP3-R.
DO
Connect the Device
Make all necessary connections to the CP3-R as shown in the illustration below.
NOTE:
Ensure that the included SD card is seated fully in the MEMORY slot prior to powering on the CP3-R.
DO
Check the Box
QUANTITY
ITEM
PART NUMBER
2
Bracket, Rack Ear, 1U
2032122
1
Cable, USB 2.0, A - B, 6’ (1.83 m)
2014966
2
Connector, 3-Pin
2003575
1
Connector, 4-Pin
2003576
1
Connector, 5-Pin
2003577
4
Connector, 8-Pin
2003580
1
Connector, 9-Pin
2003581
4
Foot, 0.5" x 0.5" x 0.23", Rubber, Black
2002389
4
IR Emitter Probe, with Terminal Block Connector, IRP2
4500152
1
Power Cord, 5' 10" (1.78 m)
2042043
1
Power Pack, 24 Vdc. 2.5 A, 100-240 Vac
2045873
PORT RS-232
RS-422
1
RS-485
G
GND
GND
GND
2
TX
TX (from CP3-R)
TX- (from CP3-R)
TX-/RX-
RX
RX (to CP3-R)
RX+ (to CP3-R)
Not Used
RTS RTS (from CP3-R)
TX+ (from CP3-R)
TX+/RX+
CTS CTS (to CP3-R)
RX- (to CP3-R)
Not Used
COM 1 Connections
1
RS-422 transmit and receive are balanced signals that require two lines plus a ground in each
direction. RXD+ and TXD+ should idle high (going low at start of data transmission). RXD- and
TXD- should idle low (going high at start of data transmission). If necessary, RXD+/RXD- and
TXD+/TXD- may be swapped to maintain correct signal levels.
2
A ground terminal connection is recommended but not required.
USB
LAN
G
TX
RX
G
COM2
COM1
COM3
TX
RX
G
RTS
TX
RX
CTS
G
24 Y Z G
NET
1 2 3 4 5 6 7 8 G
I/O
1
2
3
4
5
6
7
8
RELAY OUTPUT
S
1
2
3
4
G S G S G S G
S
5
6
7
8
G S G S G S G
IR - SERIAL OUTPUT
2.0A
24V
—
---
CONTACTS DOWN
MEMORY
MAC ID LABEL
SERIAL LABEL
24W MAX. CLASS 2
RELAY OUTPUT (1–8):
To contact closure
devices
I/0 (1–8):
To controllable
devices
IR - SERIAL (1–8):
To TLL/RS-232
devices
COM1:
To serial
controlled
devices
COM2/COM3:
To serial
controlled
devices
MEMORY:
SD-compatible
card slot
USB:
To storage
devices
LAN:
10BASE-T /
100BASE-TX
Ethernet to LAN
NET:
To any Cresnet
®
network device
24V, 2.0A:
From ac
power pack
Ground