background image

Wireless RF Receiver 

Crestron 

CNRFGWA

 

2  

  Wireless RF Receiver: CNRFGWA 

Operations Guide - DOC. 8086A 

Specifications 

The table below is a summary of specifications for the CNRFGWA.  

Specifications of the CNRFGWA 

SPECIFICATION DETAILS 

Power Requirements 

3 Watts (0.125A @ 24VDC) 

Communications 

One-way high frequency RF (433.92 or 418 MHz) 

Operating Range 

Up to 300 feet

1

 

Default Net ID 

24 

Control System Update Files

 2, 3, 4 

  2-Series Control System 
 CEN/CN-TVAV  
 CNMSX-AV/PRO  
 CNRACKX/-DP  
 ST-CP 

 
Version C2-2.000.CUZ or later 
Version 5.10.13V.UPZ or later 
Version 5.01.35X.UPZ or later 
Version 5.01.35W.UPZ or later 
Version 4.02.04S.UPZ or later 

Dimensions 

Width:   3.25 in (8.25 cm) 
Height:  7.28 in (18.49 cm) 
Depth:   1.3 in (3.44 cm) 
Antenna length: 7.92 in (20.12 cm) 

Weight 

1.1 lb (0.5 kg) 

The location of the CNRFGWA and the orientation of the antenna are important factors in the RF 
performance. With the unit located outside of any metal enclosures, the antenna is adjusted to 
achieve the best range. The range is dependent on its placement and the building in which it is used. 
The construction of the building, obstructions, and RF interference from other devices are factors 
determining the effective range of the unit.  

The latest versions can be obtained from the Downloads | Software Updates section of the Crestron 
website (www.crestron.com). Refer to NOTE after last footnote. 

Crestron 2-Series control systems include the AV2, AV2 with Card Cage, CP2, CP2E, PAC2, 
MC2W, MC2E, MP2, MP2E, PRO2, and RACK2. 

Filenames for CNX and ST-CP update files have a UPZ extension. Files on the website may be .zip 
or self-extracting .exe files containing the .cuz or .upz file. To avoid program problems, make sure 
you are using the update file with the correct suffix letter (e.g., S, V, W, X). 

NOTE

: Crestron software and any files on the website are for Authorized Crestron 

dealers and Crestron Authorized Independent Programmers (CAIP) only. New users 
may be required to register to obtain access to certain areas of the site (including the 
FTP site). 

Physical Description 

The CNRFGWA, shown on the next page, is housed in a black enclosure with 
labeling on the front panel. Three light-emitting diodes (LEDs) on the front of the 
unit indicate the unit’s operating status. The RF antenna is attached via the BNC 
connector on the top of the unit; a four-pin connector is provided on the bottom panel 
for connection to other Cresnet devices. Two miniature rotary switches on the 
bottom panel are used to set the unit’s network ID. Four rubber feet on the back of 
the unit prevent slippage when the unit is placed in its usual operating position.  

Summary of Contents for CNRFGWA

Page 1: ...Crestron CNRFGWA Wireless RF Receiver Operations Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2003 Crestron Electronics Inc ...

Page 3: ...p 6 Programming Software 6 Earliest Version Software Requirements for the PC 7 Programming with SIMPL Windows 7 Uploading 7 Communication Settings 8 Uploading a SIMPL Windows Program 10 Problem Solving 11 Troubleshooting 11 Further Inquiries 12 Future Updates 12 Appendix Optimum RF Reception Guidelines 13 Minimize Interference 13 Gateway Placement 13 Antenna Orientation 13 Return and Warranty Poli...

Page 4: ......

Page 5: ...operates at 433 92 MHz the other CNRFGWA 418 operates at 418 MHz Except for operating frequency the units are functionally identical The gateway receives RF signals from one or more wireless one way touchpanels such as the ST 1550 ST 1550C ST 1700C and MT 500C 418 MHz only and wireless remotes such as the CNWM CNRFT 32A and 48A and CNRFHT 15A and 30A The CNRFGWA gateway translates the received sig...

Page 6: ...e unit 2 The latest versions can be obtained from the Downloads Software Updates section of the Crestron website www crestron com Refer to NOTE after last footnote 3 Crestron 2 Series control systems include the AV2 AV2 with Card Cage CP2 CP2E PAC2 MC2W MC2E MP2 MP2E PRO2 and RACK2 4 Filenames for CNX and ST CP update files have a UPZ extension Files on the website may be zip or self extracting ex...

Page 7: ...I LO SWITCHES These two rotary switches are used to set the unit s network identity code Refer to Identity Code on page 5 for details CNRFGWA Indicators Three LEDs located on the front panel of the CNRFGWA indicate the unit s status Refer to the descriptions on the next page 433 92 MHZ 50 MODEL CNRFGWA CRESTRON ANTENNA NET POWER I D SELECT SIGNAL NET 24 Y Z G LO ID CODE HI INCLUDING INTERFERENCE T...

Page 8: ...e must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The equipment generates uses and can radiate r...

Page 9: ...th of run or chain in feet PF Power factor of entire run or chain R L x PF 40 000 Where The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation Refer to the table after this paragraph Wire Gauge Values RESISTANCE R WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT5 8 7 Tripled CAT5 NOTE All network wiring must consist of tw...

Page 10: ...and open the Crestron Viewport Either launch the stand alone version of Viewport or start SIMPL Windows or VT Pro e and from the menu bar select Tools Viewport 4 From the Viewport menu select Functions Set Network ID The software checks the baud rate and then opens the Set Network ID window 5 In the Set Network ID window select the CNRFGWA from the Current Network Devices text window and verify th...

Page 11: ...MPL Windows is Crestron s software for programming Crestron control systems It provides a well designed graphical environment with a number of workspaces i e windows in which a programmer can select configure program test and monitor a Crestron control system To create a program with a CNRFGWA consult the operations and installation guide for any of the one way wireless RF touchpanels or remote de...

Page 12: ...ad it is necessary to establish communications Communication Settings NOTE For laptops and other PCs without a built in RS 232 port Crestron recommends the use of PCMCIA cards rather than USB to serial adapters If a USB to serial adapter must be used Crestron has tested the following devices with good results Belkin large model F5U103 I O Gear GUC232A Keyspan USA 19QW Other models even from the sa...

Page 13: ...ne the data bits is Eight the stop bits is One XON XOFF is not selected and RTS CTS is selected Click the OK button to save the settings and close the window Port Settings Window NOTE The parameters shown in the illustration above are the port settings for a 2 Series control system Consult the Operations Guide for the control system being used for exact parameter selection 4 To verify communicatio...

Page 14: ...t the procedure for Communication Settings that begins on page 8 has been performed 2 As shown below select File Transfer Send Program Alternatively press Alt P from the Viewport menu File transfer Send Program Command 3 The Send Program window appears as shown after this step Click Browse locate the completed file spz for PRO2 and click Open This displays the program s header information and enab...

Page 15: ...the SIMPL program Open Viewport and press F4 to poll the network Verify that the Net ID for the CNRFGWA is properly set to match the SIMPL program Net ID setting changes after CNRFGWA powered up Power down the CNRFGWA then power up to reset the Net ID Network wiring incorrect Check network cabling for solid connections and correct pinouts Unit is damaged Contact Customer Service Refer to Further I...

Page 16: ... 613 9480 2999 You can also log onto the online help section of the Crestron website www crestron com to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the CNRFGWA additional information and programming examples m...

Page 17: ...ve ample separation between the equipment and the gateway Gateway Placement Optimum reception for any RF gateway is obtained by installing the gateway in an open area or shelf with a clear line of sight no obstructions between gateway and touchpanel or wireless remote Crestron recommends placing the gateway at least five to six feet high for best results Avoid placing gateways or touchpanels remot...

Page 18: ...Wireless RF Receiver Crestron CNRFGWA 14 Wireless RF Receiver CNRFGWA Operations Guide DOC 8086A Horizontal Orientation Vertical Orientation Horizontal Toward Touchpanel ...

Page 19: ...components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application...

Page 20: ...Crestron Electronics Inc Operations Guide DOC 8086A 15 Volvo Drive Rockleigh NJ 07647 10 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: