CLWI-KPLCN

In-Wall Keypad
Installation Guide

Description

The Crestron

®

 CLWI-KPLCN is the companion keypad for CLWI dimmers and switches. 

It provides lighting and audio control from multiple locations around the home or office. 
Recall scenes, dim up and down, and adjust volume using the customizable button layout. 

Specifications

Specifications for the CLWI-KPLCN are listed in the following table.

SPECIFICATION

DETAILS

Cresnet Power Usage

0.5 W (0.02 A @ 24 Vdc)

Environmental
 Temperature
 Humidity

0° to 40 °C (32° to 104 °F)
10% to 90% RH (noncondensing)

Enclosure

Mountable in a 1-gang UK (BS 4662) electrical box 
or 1-gang European (DIN 49073) electrical box; 
Requires a FP-INTENSE or FP-PURE style faceplate 
(both not included)

Dimensions
 Height
 Width
 Depth

72 mm (2.8 in)
72 mm (2.8 in)
32 mm (1.24 in) including front face with buttons

Weight

80 g (3 oz)

Dimensions

Dimensions for the CLWI-KPLCN are shown in the following illustration.

72 mm

(2.80 in)

72 mm

(2.80 in)

32 mm 

(1.24 in)

51 mm

(2.00 in)

51 mm

(2.00 in)

21 mm

(0.82 in)

Additional Resources

Visit the product page on the Crestron website (

www.crestron.com

for additional information and the latest firmware updates. Use a QR 
reader application on your mobile device to scan the QR image.

Wiring

Make the Cresnet

®

 network NET connection, and then make the optional INPUT 

connections to the contact closure(s). Use wire no larger than 1.5 mm

2

 (16 AWG). For 

details, refer to the illustrations below.

NOTE:

  The G on the INPUT and NET ports are tied together electronically in the 

device.

Earth

Cresnet

Input

Occupancy 

sensor

Contact closure 

input

Doorbell 

switch

1

2

G

NOTE:

  The contact closure input has the following rating:

•  Digital Input: Rated for 0—24 Vdc, input impedance 200 kΩ, logic  

threshold 1.24 Vdc.

•  Analog Input: Rated for 0—10 Vdc, protected to 24 Vdc maximum, input 

impedance 200 kΩ.

•  Programmable 5 volts, 2 kΩ pull up resistor per pin.

Installation

The CLWI-KPLCN can be mounted in a single-gang or multigang electrical box.

Single-Gang Installation

To install in a single-gang electrical box.

NOTE:

  Electrical box depth must be 35 mm (1.38 in) or deeper.

NOTE:

  Ensure that system power is off before installation.

1.  Push the wires back into the electrical box and fasten the device to the electrical box 

with the provided screws. 

NOTE:

  Use care when placing the device in the electrical box. Pinched wires 

may cause a short circuit.