Crestron
CEN-TVAV
Ethernet Enabled Programmable TV/AV Controller
Obtaining Communications
To upload program files to the CEN-TVAV, it is necessary to first obtain
communication with the device. Communication with the CEN-TVAV can be
established via the local RS-232 port or TCP/IP. RS-232 communications is required
to set IP address initially. Then TCP/IP communication is available.
Communication via RS-232 Port
Prior to completing the following steps, be sure the communication cable is properly
connected as described in “Cable Configuration for Programming” on page 8.
1. Make sure that no programs accessing the COM port of the PC are
running.
2. Select
Start | Programs | Crestron
| SIMPL Windows
to start SIMPL
Windows.
3. SIMPL Windows responds with an opening splash screen and may
display the “What do you want to do?” dialog box. If so, close the
dialog box.
4. As shown below, select
Tools | Viewport
to open the Crestron
Viewport dialog box.
Accessing the Viewport
5. Refer to figure below. From the
Setup
menu, verify that
Auto Baud
Search
is checked.
Verifying Auto Baud Search
Operations Guide - DOC. 5720A
Ethernet Enabled Programmable TV/AV Controller: CEN-TVAV
•
17