Multi-Press 

The multi-press button model triggers different actions each time the button is 
pressed, to a maximum of 10 button presses. If the button is not pressed after a 
specified period, a timeout event occurs and the button resets. Thus, the next button 
press triggers the first event. A timeout is also an event that can trigger actions. If the 
timeout period is set to 0 seconds, then the timeout event never occurs and the button 
simply cycles through each press action. By default, this button model generates 
momentary feedback for each press, and blinks once when the timeout event occurs.  

Tap and Hold 

The tap and hold button model triggers different actions depending on whether the 
user taps the button, or presses and holds the button for a specified ‘hold time’. By 
default, this button model generates momentary feedback for a tap and blinking 
feedback for a hold.  

Timeout 

The timeout button model triggers one or more actions when the user presses the 
button, as with a single press button model. If the button is not pressed again for a 
specified time (as set in the timeout field) then a timeout event occurs, which also 
triggers actions. Pressing the button when the timer is still counting re-triggers the 
press event and restarts the timer. By default, this button model generates 
momentary feedback while the button is pressed, and blinks when the timeout 
occurs.  

Press and Release 

The press/release button model triggers one set of actions when the button is pressed 
and a different set of actions when it is released. In this way, you can assign actions 
to both the rising and falling edge of the button press signal. By default, this button 
model generates momentary feedback.  

Master Raise/Lower 

A master raise or lower button model raises or lowers all the lights associated with 
the last button that was pressed on the keypad.  

Learnable Lighting 

Learnable lighting is a button model modifier. The toggle and single press have this 
option that allows the end user to dynamically change and resave the lighting levels 
programmed to the press event. To use this feature, simply manually adjust light 
levels for a given scene. Then press and hold the scene button that has learnable 
lighting selected.  

Feedback Types 

In addition to button models, each model also has selectable feedback types. Some 
feedback types are applicable to all button models while others are more specific.  

Always On 

The button’s feedback is always active (e.g., LED is always illuminated).  

Reference Guide – DOC. 6282 

Crestron Demonstration Case: C2N-DEMO Lighting Case  

  5 

Summary of Contents for C2N-DEMO

Page 1: ...Crestron C2N DEMO Lighting Case Reference Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Case 1 Introduction 1 Features and Functions 1 Case Contents 2 Setup 2 System Functionality 4 Button Models 4 Feedback Types 5 Interfaces 6 Appendix Factory Settings 17 Return and Warranty Policies 1...

Page 4: ......

Page 5: ...in mind to give customers a basic understanding of Crestron automation and lighting systems The Lighting Case is programmed entirely in Crestron D3 Pro programming software to allow for a more realis...

Page 6: ...LIGHTS DINING CHANDELIER GUEST BEDROOM DOWNLIGHTS GUEST BATHROOM DOWNLIGHTS Setup Complete the following steps to setup your portable Lighting Case 1 Apply Power Open the case lid simply plug the supp...

Page 7: ...on your laptop Use the Ethernet cross over cable supplied with the Crestron C2N DEMO Interface Case to connect the Ethernet port on the Interface Case with the Lighting Case Ethernet port marked LAN...

Page 8: ...e lights assigned to this button That is each time the dim operation is activated the lights dim in the opposite direction from the last dimming operation If all the lights are currently off then the...

Page 9: ...Pressing the button when the timer is still counting re triggers the press event and restarts the timer By default this button model generates momentary feedback while the button is pressed and blinks...

Page 10: ...urce Device list the Output Signal list provides the digital outputs per the device Once you select the device and output signal the button s feedback is active for as long as that output signal is hi...

Page 11: ...wnlights Dining Sconces When this button is pressed it turns on all loads to a preset level over a defined period Button 2 MUSIC When this button is pressed the first time it turns on the virtual audi...

Page 12: ...When the button is held the relay closes Button 3 K TEMP This button changes the CHV THSTAT s set point up by one degree with each press Have your customer watch the front panel display of the thermo...

Page 13: ...d then off again on press 2 Button 4 DOWN LIGHTS BM Toggle Dim FB Toggle Loads Bath Downlights On press 1 this button turns the load to a preset level and then off again on press 2 Button 5 FAN BM Tim...

Page 14: ...WN LIGHTS BM Toggle Dim FB Toggle Loads Dining Downlights On press 1 this button turns the load to a preset level and then off again on press 2 Button 5 MUSIC This button toggles the audio system for...

Page 15: ...M Single Press Learnable FB On when ALL lights are at PRESET LEVEL Loads Bath Vanity Bath Ceiling Lights Bath Downlights When this button is pressed it turns on all loads to a preset level over a defi...

Page 16: ...oad turns on until the timeout occurs at which point the load shuts off If the button is pressed before the timeout occurs the timer resets Button 9 MUSIC This button toggles the audio system for the...

Page 17: ...BM Toggle Dim FB Toggle Loads Rear Downlights On press 1 this button turns the load to a preset level and then off again on press 2 Button 4 FAN BM Multi press FB Connected to Fan Loads Ceiling Fan Th...

Page 18: ...lights Family Rear Downlights Family Lamp Entry Chandelier Kitchen Downlights Kitchen Pendants Breakfast Chandelier Master Bed Lights Master Bath Lights Hall 1 Lights Hall 2 Lights When this button is...

Page 19: ...L This button decreases the volume level of the virtual audio system The feedback LED illuminates only while the button is pressed C2N DB12 Entry 1 532 MP3 1 788 1 067 1 696 4 158 VOL OFF CD 2 696 VOL...

Page 20: ...This button turns on the virtual audio system and selects the MP3 server for the source Button 10 VOL This button lowers the volume level of the virtual audio system Button 11 CD This button turns on...

Page 21: ...se C2N DEMO Interface Case IP address is 192 168 40 11 Subnet mask is 255 255 255 0 Default router is 192 168 40 10 C2N DEMO Lighting Case LAN A IP address is 192 168 1 2 Subnet mask is 255 255 255 0...

Page 22: ...s on NAT can be found in the latest version of the NAT Reference Guide Doc 6001 which can be found on the Downloads Product Manuals page of the Crestron website www crestron com 18 Crestron Demonstrat...

Page 23: ...amps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the...

Page 24: ...Crestron Electronics Inc Reference Guide DOC 6282 15 Volvo Drive Rockleigh NJ 07647 09 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: