DMS-R-IM
Interpreting HMI
April 7, 2021
Digital Modular System - Rinse
5-16
5.7
Misc. Screen
NOTE
“
*OPTIONAL
” wording will be displayed on the touch
screen when the particular option is not purchased by user or
the option is not enabled in the Setup 6 screen.
Note
: User can enable/disable options if applicable in the
Setup 6 screen by access level as Administrator.
NOTE
DISCLAIMER:
Sonic power setting range is from 10% to 100%.
Please be informed that the power setting lower than 40% will
not have direct proportional with the actual output power on
the following generators,
40% for Martin Walter ultrasonic generator (58kHz,
132kHz and 192kHz)
40% for Megasonic ultrasonic generator (280kHz, 360kHz
and 470kHz)
60% for Megasonic MS1 ultrasonic generator (1MHz)
Misc. screens allow user to view and configure special functions at the
respective stations, such as:
Displays individual ultrasonic generator power output (W).
*
Set sonic generator power (%).
*
Set sonic power output low limit alarm set point during
Manual
mode
operation.
*
Set alarm silence timer.
*
View tank liquid conductivity, resistivity, pH, brix and recirculation
flowrate and set high and low alarm limit set point.
Select mode selection.
Select enable/disable cycle complete buzzer alert option.
*
Set initial fill time to fill chemical.
*
Set weir pump delay off time.
*
Set manual timed fill setting.
In Misc. screen, user is able to configure date and time displayed on HMI touch
screen.
Note
: “
*
” is optional item.