background image

5925 Heisley Road • Mentor, OH 44060-1833

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Convection

Humidity Oven

FL-2373

Rev. 4 (6/15)

Page 12 of 14

ITEM DESCRIPTION

Part No.

ITEM DESCRIPTION

Part No.

1. Switch (On/Off)

0808-125

8. Blower Kit

0769-182-SS-K

2A. “DE” Retherm Control

0848-092-23-K

9.  Contactor

0857-026

2B. “DX” Retherm Control

0848-092-07-K

10. Terminal Block, rear

0852-093

Sensor

0848-091-K

11. Hi Limit Switch

0848-077

3. Humidity Thermostat

12. Transformer

0769-197

Digital Control

0848-092-05-K

13. Relay

0857-102

3a. Sensor

0848-091-K

14. Fan Sw itch

0848-034

3b. Sensor bushing

0851-023

16. Alarm Assy

0908-009-01

5. Vent Fan

0769-174

For “DX” Ovens Only:

6. Fan Guard

0769-167

Connector, Probe (not shown)

0848-106-02

7. Fuse

0807-155

Food Probe 6” Long, 48” Leads

0848-113

Fuse Holder

0807-150

Food Probe 6” Long, 28” Leads

0848-112

Electrical Replacement Parts:

TOP VIEW

WITHOUT COVER

REAR VIEW

FRONT VIEW

1

2B

3

5

5

5

6

6

6

7

8

8

9

10

11

11

12

13

13

14

15

18

18

17

FRONT VIEW

TOP VIEW

WITHOUT COVER

REAR VIEW

FL-2356

ELECTRICAL REPLACEMENT PARTS 

(RO151FW1332D IS SHOWN)

ITEM DESCRIPTION

8000W, 1PH

8000W, 3PH

4700W, 1PH

4700W, 3PH

15

Power Cord

0810-124

0810-132

0810-163

0810-164

18

Heater Kit, 208V

0811-306

0811-306

0811-311

0811-311

18

Heater Kit, 240V

0811-305

0811-305

0811-312

0811-312

17

Strain Relief

0818-061

0818-050

0818-102

0818-050

REPLACEMENT PARTS

Include all information on nameplate when ordering parts

2A

  2A: "DE" RETHERM CONTROL

 2B: "DX" RETHERM CONTROL

“DE” RETHERM CONTROL

Summary of Contents for AquaTemp

Page 1: ...22 0393 www crescor com INSTALLATION OPERATION and MAINTENANCE MANUAL for Cres Cor AquaTemp HUMIDITY CONVECTION OVENS Convection Humidity Oven FL 2373 Rev 4 6 15 Page 1 of 14 CO151FWUA12DE CO151FWUA12...

Page 2: ...11 Hot Unit Replacement Parts 12 Wiring Diagram For 208 240 Volt 3 Phase 13 Wiring Diagram for 208 480 Volt 3 Phase 14 SERVICE POLICY and AGENCY LIST FL 1400 WARNING TO REDUCE THE RISK OF FIRE OR ELE...

Page 3: ...ving jurisdiction of enforcement of the codes will have the responsibility for making interpretations of the rules Use of treated water is recommended for proper operation and to maintain warranty It...

Page 4: ...tomatically switches to allow you to set HOLD temp Continue to step 1 below Holding To use as holding cabinet only skip steps 1 4 above and press HOLD button Complete steps 1 3 below 1 Turn the contro...

Page 5: ...temperature The oven will switch from COOK to HOLD mode when the probe reaches this temp 2 Push the knob to set the temperature 3 Oven will switch to PREHEAT mode and control will display PrEHt Runnin...

Page 6: ...a saved recipe Quick Recipe Note You can set Quick Recipes for recipes that you use often This way when you press a recipe group button and press start that recipe will start cooking without searching...

Page 7: ...NOTE These humidity values then are set and switch automatically based upon which Roast N Hold mode it is in The DISPLAY BUTTON momentarily shows the approximate relative humidity in the oven When wa...

Page 8: ...INTENANCE WATER PAN Drain wipe and fill water pan daily Clear vinyl drain hose is provided 1 Push hose onto drain nozzle under the base 2 Turn knob to open the drain To Fully Dry Out 1 Drain until 1 8...

Page 9: ...ward or backward to adjust magnetism c Tighten screws to secure WARNING IF OVEN GETS TOO HOT OR WON T SHUT OFF DISCONNECT POWER AT BRANCH PANEL DO NOT UNPLUG CORD TROUBLE SHOOTING GUIDE 1 Cord is unpl...

Page 10: ...LD timed mode 1 Oven is in PROBE mode DX oven 2 Oven control defective 1 Cancel recipe and switch to TIMED mode 2 Replace Control will not switch from COOK to HOLD probe mode in DX ovens only 1 Oven i...

Page 11: ...MODEL PREFIX CO 151 Item No DESCRIPTION FPWUA12D FWUA12D FW1332D HWUA6D XWUA5D 20 Door Latch Kit 1006 122 01 K 1006 122 01 K 1006 122 01 K 1006 122 01 K 1006 122 01 K 21 Door Strike 1006 122 02 K 100...

Page 12: ...n 0769 174 For DX Ovens Only 6 Fan Guard 0769 167 Connector Probe not shown 0848 106 02 7 Fuse 0807 155 Food Probe 6 Long 48 Leads 0848 113 Fuse Holder 0807 150 Food Probe 6 Long 28 Leads 0848 112 Ele...

Page 13: ...LOWER MOTOR BLOWER MOTOR BLOWER MOTOR BLOWER MOTOR BLOWER MOTOR BLOWER MOTOR 6A 6A t HOLD BLOWERS COOK BLOWERS HIGH LIMIT 300F WATER PROBE MEAT PROBE AIR PROBE VENT FAN RETHERM BLOWERS WATER HEATER TR...

Page 14: ...4 7 1 9 6 3 WATER HEATER FUSES HIGH LIMIT HIGH LIMIT HIGH LIMIT 500F 500F 500F BLOWER MOTOR BLOWER MOTOR BLOWER MOTOR BLOWER MOTOR 6A 6A t HOLD BLOWERS COOK BLOWERS HIGH LIMIT 300F WATER PROBE MEAT P...

Reviews: