LEDway® and XSP Series
Direct Arm Pole Adapter Bracket
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
1 of 2
LPN00222X0001A0
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant l’installation.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
TO INSTALL:
NOTE: Use dimensions on template shown on
the back page for drilling if pole is not pre-
drilled. (Template is not to scale.)
STEP 1:
Remove any extra gaskets plugs from the foam
gasket and place gasket over (2) bolts extending
from the Mounting Plate. See
Figure 1.
STEP 2:
Insert Backing Plate behind mounting surface.
See
Figure 1.
STEP 3:
Secure Mounting Plate and gasket to mounting
surface by tightening (2) bolts from Step 1 into
the Backing Plate. Torque bolts to 120 in. lbs.
See
Figure 1.
STEP 4:
Attach the Transition Direct Arm Adapter to the
Mounting Plate by using (2) supplied bolts and
washers. Torque bolts to 120 in. lbs. See
Figure
1.
STEP 5:
Attach the Transition Direct Arm assembly
to luminaire by referencing the luminaire
installation sheet.
1
Backing Plate
Foam Gasket
Mounting Plate
Transition Direct
Arm Adapter