INSTALLATION INSTRUCTIONS

CSC-GW-CWC-W 

SmartCast

®  

Wireless Gateway with WiFi

LPN00655X0001A0_C

1 of 3

1

RJ45 Cable Port

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed 

including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  Must be installed in accordance with the NEC or your local electrical code. If you 

are not familiar with these codes and requirements, consult a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code électrique local. 

Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter 

un électricien qualifié.

3.  Indoor use only and Suitable for Damp Locations. 

Pour usage interieur seulement et convient aux emplacements humides.

4.  This equipment shall be installed and operated with a minimum distance 20cm 

between the radiator and your body.

L’équipement doit etre installe d’une facon qu’une distance minimum de 20cm soit 

maintenue entre l’emetteur et toute partie du corps.

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

•  Suitable for use in other Environmental Air Space (Plenums) 

in accordance with section 300.22,(C) of the National Electrical 

Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian 

Electrical Code, Part 1 CSA C22.1

Peut être utilisé dans de gaines transportant de l’air traité, 

conformément à la section 300.22,(C) du National Electrical Eode 

et aux articles 2-128, 12-010(3) ET 12-100 du Code Candian de 

l’électricité Premiére partie, CSA C22.1.

•  Plenum rated cables need to be used when the SWG is installed in 

a plenum.

•  SWG needs to connected to PoE networks without routing to outside 

plant connections.

•  When this product is supplied by the  Listed Direct  

Plug-In Power Unit Starwell Technology PSE-480050US it is 

intended to be used in a 25C environment up to 2000m.

T-BAR MOUNTING

 

STEP 1: 

Plug customer supplied Ethernet RJ45 
cable into the RJ45 cable port located on the 
backside of the device. See 

Figure 1.

NOTE: 

Plenum rated cables need to be used 

when the SWG is installed in a plenum.

STEP 2: 

Insert the T-Bar clip into the back of the SWG 
unit using provided screw as shown in  

Figure 2.

STEP 3: 

NOTE: 

Before you attach the SWG device, 

please save the details from the label on the 
back of the device - SSID and password. You 
will need these details to login and connect to 
the device over Wi-Fi.

To attach the SWG device to the ceiling 
T-bar, rotate the device counter clockwise 45 
degrees and apply an upward force to engage 
the T-bar clip. While maintaining the upward 
force, rotate the device clockwise 45 degrees 
to snap and lock the device to the T-bar.

STEP 4: 

Connect the supplied Ethernet RJ45 cable to 
the POE wall supply (POE Port) .

2

T-Bar Clip 

Arms

T-Bar Clip

Screw

Back of the SWG Unit