background image

1 of 2

LPN00847X0001A0_A

RUL-B Series

LED Rural Utility Luminaire

INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION

TO INSTALL:

LUMINAIRE INSTALLATION

STEP 1: 

To open cover, unscrew the D-ring by hand. See 

Figure 1.

STEP 2: 

If luminaire is being mounted on a 1.66" O.D. pole tenon or mast arm, 
proceed to Step 3. 
If luminaire is being mounted on a 2.38" O.D. pole tenon or mast arm, 
mounting bracket must be flipped. To flip mounting bracket, remove (2) 
mounting bracket bolts and (2) washers on each bolt. See 

Figure 2.

 Flip 

bracket over and loosely reinstall bolts and washers. See 

Figure 3

NOTE:

 Lock washers should be placed on bolt first followed by flat 

washers.

STEP 3: 

Slide fixture on to pole tenon or mast arm through opening on the rear 
of housing. See 

Figure 2.

STEP 4: 

Adjust leveling of fixture from side to side. To level from front to back, 
slide pole to different Adjustment Steps in housing. Each step changes 
the angle in 2.5° degree increments. See 

Figure 4 on the back page.

 

STEP 5: 

Once desired position is achieved, use 9/16" socket wrench to tighten 
mounting bolts to 240 in-lbs torque See

 Figure 2

.

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be 

followed including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  This luminaire must be installed in accordance with the NEC or your 

local electrical code. If you are not familiar with these codes and 

requirements, consult a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code 

électrique local. Si vous n’êtes pas familier avec ces codes et ces 

exigences, veuillez contacter un électricien qualifié. 

3.  Suitable for wet locations.  

Convient aux emplacements mouilles.

4.  Min. 75C supply conductors.  

Les fils d’alimentation doivent convenir pour 75C.

5.  Suitable for operation in ambient not exceeding 40°C.  

Peut etre utilise a une temperature ambiante n’excedant pas 40°C.

6. 

If mounting bolts are completely removed in the field they should 

be hand threaded (prior to use of power tools) to ensure proper 

engagement of the thread when re-installing. Failure to pre-start 

threads may result in cross-threading or stripping of the bolts during 

reinstallation.

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

1

D-ring Screw

NOTES:

•  For use with 120-277 VAC.
•  Nema

®

 receptacle has orientation stops incorporated to 

prevent greater than 360º rotation. Do not force beyond to avoid 
damages in the receptacle and/or in the electrical connections 
inside the luminaire.

•  Prior to installation, store luminaire in a dry location protected 

from rain, dust, and outdoor environment.  If equipped with a 
photocell receptacle, do not store or install luminaire outdoors 
without immediately installing a suitable photocell, shorting 
cap, or other compatible device. Do NOT leave receptacle open 
to environmental elements.  Luminaires with a top-mounted 
photocell receptacle should not be installed in an up-light 
position or at a tilt greater than 45 degrees from the down-light 
position.

2

3

Mounting Bracket 

Bolts and Washers

Mounting Bracket

Bracket flipped 

into proper 

orientation for 

use with 2.38" 

O.D. tenon or 

mast arm

NOTE:

 Side Of Bracket With 

Large Offset Facing Away 

From Luminaire for use with 

2.38" O.D. tenon or mast arm.