IMPORTANT:
This booklet should be left with the user after
installation and demonstration
CREDA FLORIDA PLUS
ELECTRIC SHOWER
Installation and User Guide
Page 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration CREDA FLORIDA PLUS ELECTRIC SHOWER Installation and User Guide ...
Page 2: ...e time of installation Installations outside England and Wales must also conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply 5 This appliance must NOT be fitted where it may be subjected to freezing conditions 6 DO NOT switch the appliance on if you suspect it of being fro...
Page 3: ...e heater must not be mounted in the direct spray of the handset The handset must not be able to come into contact with used water in the cubicle bath or basin If it can even after the hose has been retained by the retaining ring see Diagram 8 on page 9 then a vacuum breaker must be fitted 4 Fix the riser rail with screws provided The fixing holes at the base of the brackets will be revealed by rem...
Page 4: ...nd is no longer required 2 It is recommended that a WRAS Water Regulations Advisory Scheme listed isolating valve is fitted to the incoming mains cold water before the shower unit This will allow the unit to be serviced or exchanged without having to turn off the water at the water stop valve 3 The heater can be fed from a header tank provided this has a minimum head of 7 metres 23ft 4 Ø15mm coppe...
Page 5: ...edance is less than 0 35 Ohms Rating Cable Sizes Fuse MCB Cable Length 8 5 7 8kW 240 230V 6 0mm 10 0mm 40A Type B MCB 27m Max 45m Max 6 0mm 10 0mm 45A BS 1361 fuse 12m Max 21m Max 9 5 8 7kW 240 230V 6 0mm 10 0mm 40A Type B MCB 27m Max 45m Max 6 0mm 10 0mm 45A BS 1361 fuse 12m Max 21m Max 10 5 9 6kW 240 230V 10 0mm 45A BS 1361 fuse 12m Max Remember to upgrade the cable if it runs in thermal insulat...
Page 6: ...t are not blocked 7 DEMONSTRATE OPERATION TO USERS It is recommended that the shower unit and hose etc be cleaned using a soft cloth and that the use of abrasive or solvent based cleaning fluid be avoided especially on any plated finishes We recommend that before any cleaning the isolating switch be turned off thus avoiding accidentally switching on the shower WARNING YOU MUST REGULARLY INSPECT TH...
Page 7: ... Once a temperature setting to your liking has been achieved knob C will rarely need adjusting You must however take into account required adjustments for variations of incoming mains water temperature between summer and winter see Effect of Seasonal Incoming Water Temperature Changes page 10 6 When you have finished showering push button B only You have no need to adjust knobs A or C Switch off t...
Page 8: ...sure has not fallen so far as to let pressure switch cut out e g Another tap drawing water off Raise position of shower handset Broken parts Please contact our After Sales Service Department PROFESSIONAL SERVICE If the previous Self Help checks fail to restore the performance you should seek professional help The person who installed the shower is probably the best one to investigate and correct i...
Page 9: ...at No 93793757 PRV Washer Cat No 93795817 We offer a technical advisory service on the telephone to installers and other customers with problems in the field Please call our technical team on 0844 372 7766 UK ONLY Or alternatively email us on Service request redringxpelair com Remember to quote the exact type of shower as written on the front of the shower and on this leaflet The model and serial ...
Page 10: ...nce protection should an excessive build of pressure occur within the shower Effect of Seasonal Incoming Water Temperature Changes The required water temperature is achieved by adjusting the rate of water flow Diagram 10 shows the principle involved in relating temperature rise to flow rate The higher the water rate the lower the temperature and vice versa The temperature of the water supplied fro...
Page 11: ...e has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance including the build up of limescale It is the responsibility of the installer to check that the installation parameters meet the requ...
Page 12: ...d in two positions so you are always only one step away from maximum power 3 If the water is not at your desired showering temperature turn knob C a small amount until you reach the desired showering temperature Turn clockwise for cooler Turn anti clockwise for warmer 4 When you have finished showering press the start stop button B again The indicator lights will go out 5 Wait for the water to sto...