PN 12069 R072208
40
ASSEMBLY
4.22 elecTRical WiRinG
Figure 39, Switch plate assembly
Mount the switch plate assembly in a convenient place inside
1.
the cab (Use either velcro or bolts).
Run the red wires with fuse (15 Amp & 6 Amp) to a power
2.
source. Use actuator switch harness (if provided and combine
is equipped with same type of auxiliary power supply).
Run the black wires to a suitable ground or to the actuator
3.
switch harness ground wires.
Route the long harnesses along the combine and header
4.
to the actuators (15
Amp Manifold Tilt; 6 Amp Air Volume)
and plug in.
Mount the intermediate harness connectors to a convenient
5.
location on the combine feeder house.
Place all controls in neutral or off, stop combine engine, set
parking brake, remove ignition key, wait for all moving parts to
stop, then properly block machine before servicing, adjusting,
repairing, or unplugging.
WaRninG
Disconnect the intermediate harness connector at the feeder
house when the header is disconnected from the combine.
noTe