4
LIQUID TEMP ....................
140ºF (60ºC)
DISCHARGE CASE ...........
356T6 Aluminum, Hard Anodized
DIFFUSER ..........................
356T6 Aluminum, Hard Anodized
SUCTION CASE ................
356T6 Aluminum, Hard Anodized
with wear resistant polyurethane
liner
FRAME & OUTER CASE ...
6063T6 Aluminum, Hard Anodized
PUMP SHAFT ....................
Stainless Steel
IMPELLER .........................
Stainless Steel
HARDWARE ......................
Stainless Steel
O-RINGS ............................
Buna
SEAL:
Design
..........
Mechanical, Oil Lubricated
Material
.........
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Buna-N
Hardware -300 Series Stainless
STRAINER .........................
300 Series Stainless Steel
.25" (6.35mm) Holes
UPPER BEARING:
Design
..........
Single Row, Ball
Lubrication
....
Prelubricated high-temperature
grease
Load
.............
Radial
LOWER BEARING:
Design
..........
Single Row, Ball
Lubrication
....
Prelubricated high-temperature
grease
Load
..............
Radial & Thrust
MOTOR:
Design
..........
Hydraulic, System should include
25 micron fi ltering
PUMP
SERIES
WEIGHT
SHIPPING WT. / STD UNIT
PUMP
DOMESTIC
CUBES
7-06000
17lbs./7.7kg
23lbs./10.4kg
1.7Ft. /.05m
SECTION: A - PUMP SPECIFICATIONS: SERIES 7-06000
inches
(mm)
IMPORTANT !
1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.
2.) THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS.
3.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED
MEDIA IS A COMMON OCCURRENCE.
EXTERNAL CONNECTION
INTERNAL CONNECTION