18
National Rejectors, Inc. GmbH, Buxtehude
c
2
Configuration
s
eTTinGs
for
fillinG
anD
empTyinG
casseTTe
Correcting tube counters according to filling level sensors
Six tube counters are monitoring the exact number of coins in the tubes
and register each coin collected by and paid out from the tubes.
In addition each tube is equipped with up to four filling level sensors. If the
coin changer is supposed to compare the tube counter readings with the
measured filling levels of the sensors after a coin has been accepted or
paid out and correct the tube counters if necessary, you should activate
the automatic tube counter correction.
If the vending machine control is unable to process the automatic
correction of the tube counters, you must deactivate this function.
If the tube counter correction is deactivated, ensure that the tubes
are emptied either using the inventory keys or the service menu.
Otherwise the tube counters do not equal zero before refilling the
tubes, but the number of coins registered before emptying the tubes
(cp. separate service manual).
To activate/deactivate the tube counter correction:
Quick approach:
= Main menu > E = Settings > Operating modes > Tube counter correction
Press key ...
How often?
effect
1
1 x
You enter the main menu
2
1 x
You enter the
s
eTTinG
menu. The
required menu item has already been
selected
3
1 x
You enter submenu
o
peraTinG
moDes
4
until
Tube counter
correction
You want to activate/deactivate the
T
ube
counTer
correcTion
5
1 x
Now you can activate/deactivate the
T
ube
counTer
correcTion
6
/
until setting desired
You want the tube counters to be
corrected/not corrected according to
filling level sensors
7
1 x
You lock the setting in memory
8
1 x/2 x
You return to main menu/operating
mode
Summary of Contents for NRI Currenza C2