casseTTe
Configuring float levels
Should you wish the service personal to always fill or empty the tubes at
a filling level of a certain and always identical coin number, it is advisable
to configure so-called float levels.
First of all specify a number of coins for each change tube (see section
"Specifying float level per tube" in this chapter).
If the tubes are refilled by inserting the tube coins with the cassette installed,
you also have to activate the float-up function (see section "Activating/
deactivating float-up function" in this chapter).
If the coin cassette is going to be removed to be refilled directly, you have
to activate the automatic tube counter programming (see section "Setting
tube counters to float levels automatically" in this chapter).
Specifying float level per tube
To specify the float levels:
Quick approach:
= Main menu > E = Settings > Coin settings > Float level
How often?
effect
Ziel
1
1 x
You enter the main menu
2
1 x
You enter the
s
eTTinG
menu
3
until
Coin settings
You want to enter submenu
c
oin
seTTinGs
4
1 x
You enter the submenu
5
until
Float level
You want to enter submenu
f
loaT
level
6
1 x
You enter the submenu
7
/
until tube desired
You want to set a float level for this
tube
8
1 x
Now you can set a float level for this
tube
9
/
until required digit
You highlight the digit to be set
10
/
until required value
This value is to be set
11
Please repeat steps 9 and 10 to set the other two digits of the float level, if necessary
12
1 x
You lock the set float level in memory
13
Please repeat steps 7 to 12 to set the float levels of the other tubes, if necessary
14
1 x/2 x
You return to main menu/operating
mode