background image

PARTS LIST

ITEM

QTY

DESCRIPTION

PART NO.

1

8

Hex Hd Screw, 250 Frame

5/8-11 x 2.75" Lg, Stainless

1-97-1

8

Hex Hd Screw, 320 Frame

5/8-11 x 1.75" Lg, Stainless

1-93-1

2A

1

Adapter Plate, Cast Iron

250 Frame

014-00013-101

2B

1

Adapter Plate, Cast Iron

320 Frame

014-00014-101

3

1

Volute

014-00100-101

4

1

Impeller, Cast Iron

SEE TABLE 2

5

8

Hex Hd Screw

5/8-11 x 1.50" Lg, Stainless

1-92-1

6

1

Suction Cover

014-00102-101

7

1

Wear Ring

014-00009-101

8

1

Socket Hd Screw, 250 Frame

5/8-11 x 2.25" Lg, Stainless

11-105-1

1

Socket Hd Screw, 320 Frame

5/8-11 x 2.50" Lg, Stainless

11-106-1

9

1

Impeller Washer, 250 Frame

.656 x 2.125, Cad

014-00252

1

Impeller Washer, 320 Frame

.687 x 2.437, Cad

014-00255

10

2

Volute Gasket

014-00251

11

1

Adapter Gasket, 250 Frame

014-00253

1

Adapter Gasket, 320 Frame

014-00254

12

4Ft

Steel Chain, .312, (10,15,20,25HP - 1150RPM & 30, 40HP - 1750RPM)

625-01582

5Ft

Steel Chain, .375, (30HP - 1150RPM & 50,60,75,100HP - 1750RPM)

625-01583

13

3

Cold Shut, .375, (10,15,20,25HP - 1150RPM & 30, 40HP - 1750RPM)

625-00828

3

Cold Shut, .437, (30HP - 1150RPM & 50,60,75,100HP - 1750RPM)

625-00826

14

1

Warning Tag

625-03031

15

8

Lockwasher

5/8" Stainless

20-24-1

16

3

Leg

N014-00099

17

1

Motor

SEE TABLE 1

18

8

Stud, 320 Frame

5/8-11 x 2.00" Lg, Stainless

014-00257-401

19

8

Hex Nut, 320 Frame

5/8-11 Stainless

15-21-1

20

1

Outer Seal, (Supplied with Motor)

21

1

Shaft Key, (Supplied with Motor)

PUMP MODEL MOTOR

FRAME

TABLE 1

MOTOR WITH VARIOUS CABLE LENGTHS

25FT

30FT

40FT

50FT

75FT

100FT

125FT

150FT

6SE10036EHA 250TYZ

092999

092999XC 092999XE 092999XF 092999XH 092999XL 092999XN 092999XS

6SE10046EHA 250TYZ

093000

093000XC 093000XE 093000XF 093000XH 093000XL 093000XN 093000XS

6SE15036EHA 250TYZ

069562

069562XC 069562XE 069562XF 069562XH 069562XL 069562XN 069562XS

6SE15046EHA 250TYZ

093002

093002XC 093002XE 093002XF 093002XH 093002XL 093002XN 093002XS

6SE20036EHA 250TYZ

093003

093003XC 093003XE 093003XF 093003XH 093003XL 093003XN 093003XS

6SE20046EHA 250TYZ

093004

093004XC 093004XE 093004XF 093004XH 093004XL 093004XN 093004XS

6SE25036EHA 250TYZ

093016

093016XC 093016XE 093016XF 093016XH 093016XL 093016XN 093016XS

6SE25046EHA 250TYZ

093005

093005XC 093005XE 093005XF 093005XH 093005XL 093005XN 093005XS

6SE30046EHA 320TYZ

093017

093017XC 093017XE 093017XF 093017XH 093017XL 093017XN 093017XS

6SE30034EHA 320TYZ

093008

093008XC 093008XE 093008XF 093008XH 093008XL 093008XN 093008XS

6SE30044EHA 320TYZ

093009

093009XC 093009XE 093009XF 093009XH 093009XL 093009XN 093009XS

6SE40034EHA 320TYZ

093010

093010XC 093010XE 093010XF 093010XH 093010XL 093010XN 093010XS

6SE40044EHA 320TYZ

093011

093011XC 093011XE 093011XF 093011XH 093011XL 093011XN 093011XS

6SE50044EHA 320TYZ

093012

093012XC 093012XE 093012XF 093012XH 093012XL 093012XN 093012XS

6SE60044EHA 320TYZ

093013

093013XC 093013XE 093013XF 093013XH 093013XL 093013XN 093013XS

6SE75044EHA 320TYZ

093014

093014XC 093014XE 093014XF 093014XH 093014XL 093014XN 093014XS

6SE100044EHA 360TYZ

093015

093015XC 093015XE 093015XF 093015XH 093015XL 093015XN 093015XS

15

Summary of Contents for BARNES 6SE-EHA Series

Page 1: ...ay occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification SERIES 6SE EHA 10 30HP 1150RPM SERIES 6SE EHA 30 100HP 1750 RPM BARNES 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 0603 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com PUMPS SYSTEMS A Crane Co Com...

Page 2: ...W Fig 7 14 PARTS LIST 15 16 RETURNED GOODS POLICY 17 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT PRESSURE GAUGE KIT Other brand and product names are trademarks or registered trademarks of their respective holders Reliance is a registered trademark of Rockwell Automation Barnes is a registered trademark of Barn...

Page 3: ...re on any pump and on end suction and self priming pump the heat build may cause the generation of steam with resulting dangerous pressures It is recommended that a high case temperature switch or pressure relief valve be installed on the pump body ELECTRICAL 21 To reduce risk of electrical shock pump must be properly grounded in accordance with the National Electric Code NEC or Canadian Electrica...

Page 4: ...150 or 1750 RPM Nominal UPPER BEARING Design Single Row Ball Lubrication Grease Load Radial LOWER BEARING Design Double Row Ball Lubrication Grease Load Radial Thrust MOTOR Design NEMA B Torque Curve Air Filled Squirrel Cage Induction Insulation Class F THREE PHASE Dual Votage 230 460 Requires Overload Protection to be Included in Control Panel MOISTURE SENSOR N O Requires Relay in Control Panel T...

Page 5: ...owed provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and placed in a temperature controlled storage area B 4 Service Centers For the location of the nearest Barnes Pumps Service Center check your Barnes Engineered catalog your Barnes Pum...

Page 6: ...pplication Any splice between the pump and the control panel must be made in accordance with the National Electric Code and all applicable state and local electric codes It is recommended that a junction box be mounted outside the sump or be of at least Nema 4 construction if located within the wet well Do not use the control cable to lift pump NOTE The white wire is NOT a neutral or ground lead b...

Page 7: ... damage the motor and or pump To check the rotation suspend the pump freely momentarily apply power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from the top of the pump motor housing D 2 1 Incorrect Rotation for Three Phase Pumps In the event that the rotation is incorrect for a three phase installation interchange any two power cable leads at the ...

Page 8: ...rature Sensor White P2 Temperature Sensor Red W1 Moisture Sensor Orange W2 Moisture Sensor Green Ground Fig 2 G L1 L2 L3 G T1 T7 T2 T8 T3 T9 T4 T5 T6 MOTOR LEADS POWER Large Cable G R E E N B L A C K R E D W H I T E POWER Large Cable MOTOR LEADS G L1 L2 L3 G T1 T2 T3 T4 T7 T5 T8 T6 T9 G R E E N B L A C K R E D W H I T E Temperature Sensor Leads Moisture Sensor Leads CONTROL Small Cable S1 S2 W1 W2...

Page 9: ...r damage F 1 2 Reassembly To install wear ring 7 first apply retaining compound to the bore of suction cover 6 and then press wear ring 7 into bore of suction cover 6 until seated Position gasket 10 on volute and locate suction cover 6 on volute 3 apply thread locking compound to cap screws 5 set legs 16 into place on suction plate 6 place washers 15 on cap screws 5 that are used on legs 16 and to...

Page 10: ...20B making sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 20B over shaft and let rest on spring 20C Assemble impeller and volute as outlined in paragraph F 1 2 WARNING DO NOT DISASSEMBLE THE RELIANCE MOTOR IN ANY WAY EXCEPT FOR OUTER SEAL AS THIS WILL VOID WARRANTY F 3 Motor Cables Inner Shaft Seal Service The Submersible pump motor is manufactured by ...

Page 11: ...Clean impeller cavity and inlet of any obstruction 9 Loosenunion slightly toallow trapped air to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump ...

Page 12: ...ign configuration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information G 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specific to e...

Page 13: ...Fig 6 320 FRAME 250 FRAME 13 ...

Page 14: ...Fig 7 14 ...

Page 15: ...VARIOUS CABLE LENGTHS 25FT 30FT 40FT 50FT 75FT 100FT 125FT 150FT 6SE10036EHA 250TYZ 092999 092999XC 092999XE 092999XF 092999XH 092999XL 092999XN 092999XS 6SE10046EHA 250TYZ 093000 093000XC 093000XE 093000XF 093000XH 093000XL 093000XN 093000XS 6SE15036EHA 250TYZ 069562 069562XC 069562XE 069562XF 069562XH 069562XL 069562XN 069562XS 6SE15046EHA 250TYZ 093002 093002XC 093002XE 093002XF 093002XH 093002...

Page 16: ...50RPM 014 00117 117 12 875 014 00116 119 014 00117 119 12 750 014 00116 121 014 00117 121 12 625 014 00116 123 014 00117 123 60HP 1750RPM 12 500 014 00116 125 014 00117 125 12 375 014 00116 127 014 00117 127 12 250 014 00116 129 014 00117 129 12 125 014 00116 131 014 00117 131 12 000 014 00116 133 15HP 1150RPM 014 00117 133 11 875 014 00116 135 014 00117 135 11 750 014 00116 137 014 00117 137 50HP...

Page 17: ...of the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable ...

Page 18: ...ield performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control Components or accessories suppl...

Page 19: ...bottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Motor measured at pump control Red Black Ohms Red White Ohms White Black Ohms Resistance Of Ground Circuit Between Control Panel and Outside of Pump Ohms MEG Ohms Check of Insulation Red to Ground White...

Page 20: ...n Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks Does check valves operate properly Flow Does station appear to operate at proper rate Pump down time Noise Level High Medium Low Comments Equipment Difficulties during start up MANUALS Has operator ...

Page 21: ...ERIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service Group IMPORTANT If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Page 22: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE ...

Reviews: