7
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LO
A
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
4SHVB Pump
4SHVB150N2
15.0
208
3
60
3450
E
54.1
1.2
59.0
195.7/88.5
125498
8/4 - 18/4
1.12 ± .02
.247/.988
23
0
48.9
1.2
57.1
125498
8/4 - 18/4
1.12 ± .02
46
0
24.4
1.2
28.5
125497
12/4 - 18/4
.87 ± .02
4SHVB15052
15.0
575
3
60
3450
E
19.5
1.2
22.8
70.8
125497
12/4 - 18/4
.87 ±
.02
1.61
4SHVB20082
20.0
230
3
60
3450
J
50.8
1.2
59.0
189.0
125498
8/4 - 18/4
1.12 ± .02
.089/.356
460
25.4
1.2
29.7
125497
12/4 - 18/4
.87 ± .02
4SHVB20052
20.0
575
3
60
3450
J
20.3
1.2
23.8
151.2
125497
12/4 - 18/4
.87 ±
.02
.545
4SHVB25042
25.0
460
3
60
3450
G
30.8
1.2
36.7
189.0
125499
8/4 - 18/4
1.12 ±
.02
.356
4SHVB25052
25.0
575
3
60
3450
G
24.6
1.2
29.4
151.2
125497
12/4 - 18/4
.87 ±
.02
.545
4SHVB30042
30.0
460
3
60
3450
F
36.7
1.2
44.3
189.0
125499
8/4 - 18/4
1.12 ±
.02
.356
4SHVB30052
30.0
575
3
60
3450
F
29.4
1.2
35.4
151.2
125499
8/4 - 18/4
1.12 ±
.02
.545
4SHVB150N4
15.0
208
3
60
1750
E
51.8
1.2
59.0
206.6
125498
8/4 - 18/4
1.12 ± .02
.187/.748
230
46.9
1.2
54.3
206.6
125498
8/4 - 18/4
1.12 ± .02
460
23.4
1.2
27.2
103.3
125497
12/4 - 18/4
.87 ± .02
4SHVB15054
15.0
575
3
60
1750
E
18.7
1.2
21.7
82.6
125497
12/4 - 18/4
.87 ±
.02
1.16
4SHVBA
4SHVBA25042*
25.0
460
3
60
3450
G
30.8
1.2
36.7
189.0
125499
8/4 - 18/4
1.12
± .02
.356
4SHVBA25052*
25.0
575
3
60
3450
G
24.6
1.2
29.4
151.2
125497
12/4 -18/4
.86
± .02
.545
4SHVBA30042
30.0
460
3
60
3450
F
36.7
1.2
44.3
189.0
125499
8/4 - 18/4
1.12
± .02
0.356
4SHVBA30052
30.0
575
3
60
3450
F
29.4
1.2
35.4
151.2
125499
8/4 - 18/4
1.12
± .02
0.545
4SHVBA150N4
15.0
208
3
60
1750
F
51.8
1.2
59.0
206.6
125498
8/4 - 18/4
1.12 ± .02
.084 / .337
230
46.9
1.2
54.3
206.6
125498
8/4 - 18/4
1.12 ± .02
460
23.4
1.2
27.2
103.3
125497
12/4 - 18/4
.86 ± .02
4SHVBA15054
15.0
575
3
60
1750
F
18.7
1.2
21.7
82.6
125497
12/4 - 18/4
.86 ±
.02
0.51
Moisture and
Temperature sensor leads are integral to power co
rd.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS
@ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
▲ Cord Suffi
x: XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
▲ Cord sold separately (After March-2016 ONL
Y). Pumps built Bef
ore March-2016 refer to Cord
Assembly Kit, see page 28.
* Select impeller diameter when ordering.
CHART ‘B’