Page 1: ...FirstUse of This Product Save ThisManual For FutureReference e CRAFTSMAN Model No 390 303302 CRAFTSMANPROFESSIONAL Model No 390 303491 I RRFTIMRW PEDESTAL SUMP PUMP Safety Instructions Operation Installation Service Repair Parts Sears Roebuck and Co Hoffman Estates IL 60179 U S A PRINTED iN U S A Form No F642 2001 Rev 4 19 04 ...

Page 2: ...signal words and be alert to the potential for per sonal injury _ warns about hazards that will cause serious personal injury death or major property damage if ignored _WARNING_ warns about hazards that can cause serious personal injury death or major property damage if ignored A CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored The word NOTICE ...

Page 3: ...PT PUMP INSTALLATION Check your local Electrical and Plumbing odes before in stalling pump You nlust comply with their rules Set tile pump on the bottom of the stlnlp luakiug sure that it sits solidly and is level Be sure there is cnotlgh space arottlld the punlp to allow tile s vitc l I ree MOVelncnt as tile stlnlp veater level cllallgCS I o not Jllstall un clay earth or salld _ CAUTION Risk of f...

Page 4: ...r rises in the sump the float lifts the switch rod The buoyancy will push tim switch arm up tnd mm tile switch on When the water is ptmlped out of tile sump the lloat drops do _ ll again Tim weight of the loat will all w the rod and switch arm to li wer and turn tile dntiner switch off DO NOT ALLOW PUMP TO RUN DRY Pump should not be allowed to tun dry prior to shutting off To do so voids the warra...

Page 5: ...tional loads such as lights must he added tu the listed load and the genenttor sized ac cordingly Pump Minimum Watt Motor HP Rating of Generator 1 3 2 200 1 2 2 800 SERVICE General _ WARNINGIRisk of electric shock When servicing pump always disconnect power to electrical outlet and remove pump electric cord from outlet Inspect sump pump and system components monthly Keep free of debris and foreign...

Page 6: ...rated U30 932ZP RP0005257 RP0005246A 101 33P SC004 116 FT0013 63 RP005168S RP0005249 U30 929ZP 2773 RP0005248 U17 318 Description Motor withCord and Switch Screw 8 x 1 2 Hex Head 2 Required Shaft Column Impeller Assembly Screw 8 18 x 3 8 Self Tap Float Rod Rod Guide Screw 8 x 1 Phillips Head Switch Float Stop 2 Required Cord and Plug If motor fails replace entire pump 6 ...

Page 7: ...5249 U30 929ZP Description Motor withCord and Switch Set Screw 4 Required Shaft Column Volute Impeller Base Plate Screw 8 32 x 1 2 Hex Head 8 Required Rod Guide Screw 8x1 Phillips Head 10 RP0005248 11 FT0013 63 12 RP005168S 13 2773 U17 318 U78 130P Not illustrated May be purchased locally If motor fails replace entire pump Rod Bushing 2 Required Float Rod Switch Cord and Plug 1 1 2 x 1 1 4 Reducer...

Page 8: ...iror replacementpartsyouneed Call7 am 7 pm 7 daysa week 1 800 366 PART 1 800 366 7278 Forin homemajorbrandrepairservice Call24 hours a day 7 daysa week 1 800 4 REPAIR 1 800 473 7247 For the locationof a SearsRepairServiceCenterin yourarea Call24 hours aday 7 daysa week 1 800 488 1222 ForinformationonpurchasingaSears MaintenanceAgreement or to inquire aboutan existingAgreement call g am 5 pro Monda...