Super Shot 60 Propane Melter Part Manual
Chapter 8 Troubleshooting
©2018 by Crafco, Inc. All Rights Reserved
………………...…………………………..……………...Illustrated Parts List 8-31
Step
Possible Cause
If . . .
6
Move back to the control box.
Is there 12 Vdc between the pump relay base
#14 terminal green trigger wire and the #13
terminal black ground wire, when the trigger is
pulled?
• Yes, go to Step 7.
• No, check for a broken wire or loose wire
at the relay base on both the green trigger
wire and the two black ground wires. Also
check for any damage to the green trigger
wire from the junction box to the control
box.
7
Is there 12 Vdc between the pump relay base
#12 terminal red blk wire and the #13 terminal
black ground wire?
• Yes, go to Step 8.
• No, go to Step 7a.
7a
Is there 12 Vdc between the terminal block red
black wire and the pump relay base #13 terminal
black ground wire?
• Yes, check a broken wire or loose wire at
the pump relay base #12 terminal.
• No, Crafco, Inc. and speak to a service
technician.
8
Is there 12 Vdc between the pump relay base #8
terminal blue pump wire and the #13 terminal
black ground wire, when the trigger is pulled?
• Yes, go to Step 9.
• No, replace the pump relay cube.
9
Move to the rear of the machine. Remove the
cover over the hydraulic manifold.
Is the amber light "ON" when the wand trigger is
pulled?
(Looking down at the top of the hydraulic valve,
Pump forward is the din plug lower right-hand
corner, Refer to
.)
• Yes, go to Step 9c.
• No, go to Step 9a.
Table 8-26 Pump Electrical Troubleshooting (continued)
Summary of Contents for SUPER SHOT 60
Page 1: ...Parts Manual 26616 Revision C SUPER SHOT 60 PROPANE MELTER ...
Page 4: ...Super Shot 60 Propane Trailer Melter PN 43300 Super Shot 60 Propane Skid Melter PN 50750 ...
Page 14: ......
Page 22: ......
Page 62: ......
Page 66: ......
Page 102: ......
Page 136: ......
Page 139: ......
Page 140: ... 2018 Crafco Inc ...