Super Shot 125 Diesel Melter Part Manual
Chapter 8 Troubleshooting (43600, 43800 and 45500)
©2017 by Crafco, Inc. All Rights Reserved………………...……………Troubleshooting (43600, 43800, and 45500) 8-19
RVP PUMP
PRESSURE RELIEF
SET @ 1000 PSI
RVA AGITATOR
PRESSURE RELIEF
SET @ 1000 PSI
PRESSURE
RELIEF JAM NUT
ALLEN SCREW
Fig. 8-6 Hydraulic Valve Pressure Setting
Agitation Direction = Counterclockwise
Hydraulic Flow Standard = 9.04 GPM @ 2400 RPM
Hydraulic Flow Compressor = Front section 16.61 GPM @ 2800 RPM
Hydraulic Flow Compressor = Rear section 7.03 GPM @ 2800 RPM