The 

VG200

is the state of the art digital electronic vacuum

gauge designed to accurately monitor the entire evacuation

process from start to finish. The VG200 has been designed to

be rugged and reliable. The VG200 incorporates 2 keys and

an LCD display. One key simply turns the unit ON and OFF.

The other key allows the user to change between MICRONS,

MILLIBAR, TORR and INCHES HG VAC any time during the

operation of the unit. An advanced ambient compensating

design automatically compensates for varying temperature

conditions with no manual adjustments needed. 

INCLUDED: gauge hook, adapter “T-fitting” and a padded

vinyl case.

VG200

DIGITAL VACUUM GAUGE

 

Owner ’s Manual

#73-170-Rev.D_VG200_Manual  7/24/14  3:24 PM  Page 1

Summary of Contents for VG200

Page 1: ... keys and an LCD display One key simply turns the unit ON and OFF The other key allows the user to change between MICRONS MILLIBAR TORR and INCHES HG VAC any time during the operation of the unit An advanced ambient compensating design automatically compensates for varying temperature conditions with no manual adjustments needed INCLUDED gauge hook adapter T fitting and a padded vinyl case VG200 D...

Page 2: ...ttach the unit in the following configurations a Connect directly to the service manifold gauge set using the included T fitting b Connect directly to the refrigerant system service ports using the included T fitting c Connect directly to one of the two of the refrigerant systems service ports d Connect directly to the vacuum pump using the included T fitting e Mount directly on to a 4 or 5 valve ...

Page 3: ...vacuum pump and watch the display as it measures the performance of the vacuum pump Note Different sizes and brands of vacuum pumps will experience varied results Check the specifications published by the manufacturer of your vacuum pump to determine the ultimate vacuum level your pump can achieve Many published specifications state that pumps rated between 2 8 CFM should experience an ultimate va...

Page 4: ...ted thermistor bridge with integral temperature compensation from 0 to 50 C 32 to 122 F OPERATING PRESSURE RANGE Atmospheric pressure to 0 microns Maximum Working pressure 600 PSIG BURST PRESSURE 3000 PSIG OPERATING RANGE Atmospheric to 0 microns ACCURACY 10 of Reading OPERATING TEMPERATURE RANGE Compensated accuracy as stated 0 C TO 50 C 32 F TO 122 F Non compensated add 0 5 error for every C out...