TR600 Series

Refrigerant Recovery Machines

THIS EQUIPMENT HAS BEEN VERIFIED BY UNDERWRITERS LABORATORIES INC. TO MEET EPA’S MINIMUM REQUIREMENTS FOR RECOVERY 

EQUIPMENT INTENDED FOR USE WITH ALL SYSTEMS CONTAINING REFRIGERANTS FROM ARI740-98 CATEGORIES III, IV, AND V. UL CONTROL 

NUMBER 2HA5.

OWNER’S MANUAL (English)

 

Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E  

TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Evaluated for performance in 

accordance with Sec. 608 of 

the Clean Air Act (Feb 29, 1996) 

using AHRI-740-98 test methods.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for Pro-Set TR600 Series

Page 1: ...E WITH ALL SYSTEMS CONTAINING REFRIGERANTS FROM ARI740 98 CATEGORIES III IV AND V UL CONTROL NUMBER 2HA5 OWNER S MANUAL English Series TR600 TR610 TR600C TR610C TR600S TR600K TR600E TO BE OPERATED BY QUALIFIED PERSONNEL ONLY Evaluated for performance in accordance with Sec 608 of the Clean Air Act Feb 29 1996 using AHRI 740 98 test methods www com information itm com 1 800 561 8187 ...

Page 2: ...ings for quiet operation High impact injection molded housing Ergonomic well balanced design for easy transport No tool access suction housing for easy filter clean change Designed and manufactured in U S A with U S and globally sourced components Worldwide patents pending Less parts mean greater reliability Key Features 2 General Safety Instructions 3 Specifications 4 Controls and Features 5 Dire...

Page 3: ...e please use extreme caution WARNING TO REDUCE THE RISK OF FIRE Avoid the use of an extension cord because the extension cord may overheat However if you must use an extension cord the cord shall be 10 awg minimum WARNING Avoid breathing refrigerant vapors and lubricant vapor or mist Breathing high concentration levels may cause heart arrhythmia loss of consciousness or even cause suffocation Expo...

Page 4: ...cylinder oilless Overload Protection 15 Amp 13 Amp 10 Amp Power Consumption 1000 W Tank Overfill Switch P P Suction Pressure Gauge Outer Scale 30 hg to 500 psig 100 kPa to 3500 kPa 1 bar to 35 bar Inner Scale Discharge Pressure Gauge Outer Scale 0 550 psig 0 3800 kPa 0 38 bar Inner Scale High Pressure Shut Off 550 psig 38 bar 450 psig 31 bar 550 psig 38 bar 3800 kPa 38 bar AHRI 740 Class Refrigera...

Page 5: ...ective cap High Side Gauge Low Side Gauge Molded Rubber Grip Handle Durable Housing Air Exhaust Vents Suction Shut Off Valve Suction Port with Cleanable 100 Mesh Filter with protective cap 220 240V IEC Connector 115V Plug OR Air Exhaust Rubber Feet Air Intake www com information itm com 1 800 561 8187 ...

Page 6: ... refrigerant flow 6 Monitor amount of refrigerant in Recovery Tank WARNING Do not over fill Recovery Tank Note The unit is designed to handle large amounts of liquid refrigerant If during direct liquid recovery the compressor begins to make a slugging or hammering noise meter in the incoming liquid by closing the IN valve until the noise subsides 7 Unit will run continuously Monitor IN Gauge Set M...

Page 7: ...n in Diagram 2 EU Note The recovery tank must be rated for 38 bar 2 Open Liquid and Vapor Valve on Recovery Tank 3 Open OUT Valve on unit 4 Set Main Power Switch to ON 5 When unit starts open IN Valve on unit to start refrigerant flow 6 Monitor weigh scale for increase of weight in the Recovery Tank or view sight glass for liquid refrigerant flow WARNING Do not over fill Recovery Tank 7 Once the w...

Page 8: ...nc guarantees that all products are free of manufacturing and material defects to the original owner for one year from the date of purchase If the equipment should fail during the guarantee period it will be repaired or replaced at our option at no charge This guarantee does not apply to equipment that has been altered misused or solely in need of field service maintenance All repaired equipment w...