CPS IAQPRO SmartAir Owner'S Manual Download Page 1

Download App Now

CPS Link™

OWNER’S MANUAL

 

(English)

Latest updates: www.cpsproducts.com

 Wireless Technology

Patent #9,043,161

Version 4.3 or 

higher

IAQPRO SmartAir™

Professional Indoor Air Quality Meter

Summary of Contents for IAQPRO SmartAir

Page 1: ...Download App Now CPS Link OWNER S MANUAL English Latest updates www cpsproducts com Wireless Technology Patent 9 043 161 Version 4 3 or higher IAQPRO SmartAir Professional Indoor Air Quality Meter ...

Page 2: ...3 OVERVIEW 3 FEATURES BENEFITS 4 IAQPRO LAYOUT 5 SPECIFICATIONS 5 7 QUICK START INSTRUCTIONS 7 10 AIR QUALITY READINGS Issues Causes Solutions 11 12 APP SCREENS IAQPRO CPS Link 13 14 TROUBLESHOOTING GUIDE 15 16 WARRANTY 17 CPS LOCATIONS 17 ...

Page 3: ... NORMAL TEMPERATURE AND HUMIDITY CONDITIONS If the IAQPRO has been stored in temperature extremes it must be placed indoors unplugged in NORMAL TEMPERATURE AND HUMIDITY conditions for 6 to 8 hours before being powered ON The SmartAir is a compact professional instrument for measuring 9 different critical factors that determine the quality of indoor air After placement on an interior residential su...

Page 4: ...ors VOC Sensor Detects Volatile Organic Compounds If a value is in a Moderate to Severe range the CPS Link app will recommend one or more remedial solutions Combustible And Non Combustible Gas Sensor Particulate Matter Sensor Detects particles 2 5 µ and 2 5 10 µ microns Environmental Sensor Reads indoor temperature relative humidity and building pressure Determines if temperature relative humidity...

Page 5: ... Conforms to UL STD 62368 1 Certified to CSA STD C22 2 No 62368 1 Protective Carrying Case EVA semi rigid shell with internal compartments Agency Approvals FCC Tested and found to be compliant with FCC 47 CFR Part 15B 2017 ISED ICES 003 Issue 06 2016 CE Approvals EMC Electromagnetic Compatability Emissions EN EN 61326 1 2013 Basic Level EN 55011 2009 A1 2010 EN 61000 3 2 2014 EN 61000 3 3 2013 EN ...

Page 6: ... Indoor Comfort Zone Heating Cooling Season Temperature Humidity 2 3F 1 3C 5 of Reading 61F 16C 10 r H 93F 34C 95 r H tVOC s Total Volatile Organic Compounds 50 ppb 15 5 Minutes To 60 Minutes 0 ppb 5 000 ppb CO2 Carbon Dioxide 100 ppm 3 Of Reading 3 Minutes 0 ppm 5 000 ppm PM2 5 Fine Particulate Matter 25ug m3 for 100 ug m3 25 for 100ug m3 Immediate 0 ug 400 ug PM10 Particulate Matter 0 ug 600 ug ...

Page 7: ...ing this time period Step 2 5 Minutes Required Relocate the unit to a secure dry location OUTDOORS with access to power do not locate in direct sunlight It is OK to disconnect the unit from the INDOOR power source while relocating it to the OUTDOOR location Power unit ON and wait for 5 mins SPECIFICATIONS CONT D QUICK START INSTRUCTIONS Per World Health Organization Per Engineering Toolbox Color R...

Page 8: ...urate readings and to generate an Indoor Air Quality Test Report start a 30 minute test default setting Choose the TESTS icon upper right of screen then Choose the Air Quality option lower left of screen Choose a Standard Test 30 minutes or Custom Test If Standard Test selected touch Start Test button to begin A new screen will appear and the timer counts backwards from 30 minutes To conduct a tes...

Page 9: ... resolve indoor air quality problems a Generating a Customizable Report and Proposal After running an indoor air quality test choose View Results at the bottom of the dashboard b A screen will appear showing the Air Quality Issues Choose Continue at the bottom This will take you to the Causes and Solutions screen c A screen will appear showing the Causes and Solutions Here you can fill in your inf...

Page 10: ... under the main menu so you can view or send it at a later date Device Selection Screen Step 3 Air Quality Tests In Process Dashboard Screen Starting An Air Quality Test Touch for more information about an air quality factor Test countdown timer Legend CPS wireless device status Actual connection status QUICK START INSTRUCTIONS CONT D ...

Page 11: ...iate equipment size and adjust accordingly Building Envelope Excessive Leaking Perform blower door test Perform leak inspection of all potential leak sources windows doors chimney walls insulation High PM2 5 0 2 5 microns Dirty Ductwork Clean and sanitize ducts US EPA recommends an average 12 μg m3 or less per day over duration of 1 year Add whole home UV anti bacterial system Organic Growth on Co...

Page 12: ... registers in bedrooms 350 1 000 ppm is typical level in occupied spaces with good air exchange Inadequate ventilation Add ERV Energy Recovery Ventilation or HRV Heat Recovery Ventilation to exchange stale air with fresh air High Or Low Building Pressure Negative air pressure in summer Inspect windows doors or other openings in the building envelope for air leaks Slightly positive 02 in to 03 in W...

Page 13: ...n the COOLING or HEATING Comfort Zone trapezoid shown above Area inside BLUE or RED trapezoid shape indicates Indoor Comfort Zone for Cooling or Heating Seasons as specified by ANSI ASHRAE Standard 55 Icon indicates room temperature and humidity being measured at test location COOLING HEATING ...

Page 14: ...REENS IAQPRO CPS Link Use Pop Up Keypad to Enter Prices for Air Quality Solutions Convenient Billable Air Quality Remediation Costs Your company logo and contact information can be added to appear in all reports ...

Page 15: ...5 to 60 minutes for tVOC sensor to warm up Blue flash once every 5 seconds SmartAir is paired to your mobile device with the CPS Link app CPS Link App CPS Link App crashes Ensure mobile device is Bluetooth compatible and Bluetooth setting ON in mobile device Delete the CPS Link app from your mobile device Then reinstall the latest CPS Link app from App Store or Google Play on your mobile device Ca...

Page 16: ... A blue dot is visible in the upper right corner of the Performance Screen or Test Screen The LED light bar will flash blue about once every 5 seconds VOC sensor doesn t seem to provide accurate readings User must set tVOC Sensor Baseline PRIOR TO INITIAL USE See Quick Start Instruction Guide If the SmartAir is turned OFF after conducting tests at various locations on a jobsite the VOC sensor will...

Page 17: ...y does not include equipment that CPS determines is beyond economical repair For latest update to this owner s manual go to www cpsproducts com CPS PRODUCTS INC U S A 3600 Enterprise Way Miramar Florida 33025 USA Tel 305 687 4121 1 800 277 3808 Fax 305 687 3743 E mail info cpsproducts com Website www cpsproducts com CPS PRODUCTS CANADA LTD 1324 Blundell Road Mississauga ON L4Y 1M5 Tel 905 615 8620...

Page 18: ...www cpsproducts com 79 130 Rev B ...