CPR’s Continuous Siphon Overflows provide the most efficient means of getting water to an external 
filter without expensive modifications to the tank.  These precision-engineered overflows skim water from 
the surface of your aquarium at flow rates up to six times greater than units with tubes.   Advantages 
such as water level adjustment, quiet operation, fish screen, and a black top to reduce algae growth all 
make the CPR Continuous Siphon Overflow the best on the market.  Please read through the set up 
directions before and during the actual set up to ensure it is done correctly. 
 
To place your overflow into operation: 
 
1.     Open the packaging carefully and inspect the unit for damaged or missing parts.  You should have: 

(1)   Overflow  body 
(1)   Fish  screen 
(1)   Pre filter screen and sponge 
(1)   Vent tube with small “O” ring 
(1)   Bulkhead assembly  
(4) Adjustment screws 
(1) Airline 
(1)  Aqua Lifter pump and Acrylic Lid (included in Deluxe models) 

If any items are damaged or missing, please contact your dealer immediately. 
 
2.    Before using the overflow for the first time it is important to decide where to position the unit.  It is 

best to have the overflow as far away from the inflow as possible to reduce turbulence.  It is also 
important to check the capacity of your sump as well as the flow rate of your return pump on your 
filtration system to prevent possible overflow.  It will be necessary to add water to the system after 
it begins running.  The amount of water that you will need to add will depend on the sump size and 
design. 
 

3.   Assemble the bulkhead fitting as shown in diagram A.  Insert the pre-filter screen into the bulkhead 

and place the pre-filter sponge over the screen.  Insert the vent tube into the hole at the top of the 
pre-filter screen.  The “O” ring can slide up or down to adjust the height of the vent tube once the 
unit is operational. 

4.   Connect the bulkhead fitting to the hose going into your filtration system.  You should use 1” 

Schedule 40 PVC inserted into the slip fitting of the bulkhead.  The PVC can be run directly into the 
filter or can be attached to 1 1/4” flexible line (using the optional PVC adapter available at Ameka 
Aquatics.com).  The fewest bends in the line will ensure the quietest operation.  To prevent leaking 
from where the PVC inserts into the bulkhead, you should use PVC cement to secure it into place.   If 
using adapters other than PVC, All-Purpose Cement should be used to secure the plumbing in place. 

 
5.   Place the unit on the edge of your tank and allow the water to fill the front chamber.  Adjust the 

lower adjustment screws so that the unit is parallel to the back of the tank. 

Summary of Contents for CS100

Page 1: ...est to have the overflow as far away from the inflow as possible to reduce turbulence It is also important to check the capacity of your sump as well as the flow rate of your return pump on your filtration system to prevent possible overflow It will be necessary to add water to the system after it begins running The amount of water that you will need to add will depend on the sump size and design ...

Page 2: ... air out from the overflow so a larger powerhead should be used Another option is to place the powerhead in the sump c Plugging the air nipple Use the airline that came with your overflow Attach one end to the air nipple on top of the overflow and a check valve on the other end to prevent air from being drawn in through the airline You will need to initially draw out the air using a Venturi powerh...

Page 3: ...ushing noise coming from the overflow This noise is caused by air trying to escape back up through the bulkhead while the water is going down The enclosed vent tube will help reduce the level of noise Place the tube through the small hole in the pre filter screen Start with the o ring at the bottom of the tube and slowly push it down into the prefilter screen until you find the point where the noi...

Page 4: ...Nut Adapter for flex hose optional Overflow Outlet Body Screen optional Diagram B Inlet Outlet tubing to sump tank or overflow Air Nipple Diagram A Air tubing to Aqua Lifter or venturi pump Aqua Lifter and lid included in Deluxe models Lid not shown ...

Reviews: