UNPACKING & INSTALLATION
2-6
D
OC
.01040044
R
EV
.6
2.6.4.1 Prime
Power
WARNING! DO NOT APPLY POWER TO THE AMPLIFIER UNTIL DIRECTED TO DO
SO IN THE PROCEDURE.
Prime power is applied to connector J1 (AC IN) located on the rear panel of the amplifier. J1 is
an IEC-60320-C20 INLET type connector; mating connector is IEC-60320-C19 cable mount. It
must be wired provide prime power of 100Vac to 240Vac
±
10 (nominal), 47-63 Hz. This voltage
is indicated on a label located on rear panel.
For nominal 120VAC Power grids, the unit must be connected to main power through a circuit
breaker or fuse rated for 20A.
For nominal 230VAC Power grids, the unit must be connected to main power through a circuit
breaker or fuse rated for 10A.
The local utility company should approve the fuse or breaker. Ensure that the fuse or breaker’s
interrupt rating meets the appropriate installation requirements.
A prime power mating connector is provided in the ship kit with the unit. The pins of the
prime power connector should be wired as indicated in Table 2-1.
Table 2-1. Primary Power Cable Connections
J1 Description
Pin 1
Line or Phase A
Pin 2
Neutral or Phase B
Pin PE
Potential Earth
Prepare the prime power cable but do not connect the cable to the amplifier at this time.
The user is responsible for supplying the appropriate connector for the main high voltage
connection at the end of the cable. Only a licensed electrician can connect the amplifier directly
to the mains.
Note: The customer is responsible for verifying this power cable
connection with their local power utility. If unsure, consult a licensed
electrician.
Summary of Contents for S4UIA
Page 4: ...INDOOR SSPA IV DOC 01040042 REV 6 This page is intentionally left blank...
Page 23: ...UNPACKING INSTALLATION DOC 01040044 REV 6 2 7 Figure 2 1 Connector Locations C band shown...
Page 42: ...INITIAL POWER ON CHECKOUT 4 10 DOC 01040053 REV 6 This page is intentionally left blank...
Page 66: ...OPERATION 5 24 DOC 01040086 REV 7 This page is intentionally left blank...
Page 80: ...SSPA FUNCTIONAL TREE 7 2 DOC 01040089 REV 4 This page is intentionally left blank...
Page 90: ...CUSTOMER WARRANTY AND SUPPORT A 2 APP 01040025 REV 1 This page is intentionally left blank...