CPG CBL15 Installation & Operation Instructions Download Page 1

 

CHARBROILER 

Installation & Operation Instructions 
 
 

Model: CBL15, CBL24, CBL36, CBL48 

CBR15, CBR24, CBR36, CBR48 

 

IMPORTANT FOR FUTURE REFERENCE 

Please  complete  this  information  and  retain  this  manual  for  the  life  of  the  equipment.  For 
Warranty Service and/or parts, this information is required. 
                                                                                                                                                         
Model Number                                          Serial Number                                  Date Purchased 
 
 

WARNING:

 For your safety, do not store or use gasoline or other flammable vapors or 

liquids  in  the  vicinity  of  this  or  any  other  appliances.  Keep  the  area  free  and  clear  of 
combustible materials. (See ANSI Z83. 14B, 1991). 

 

WARNING

Improper installation, adjustment, alteration, service or maintenance can 

cause  property  damage,  injury,  or  death.  Read  the  installation,  operating  and 
maintenance instructions thoroughly before installing, or servicing this equipment.

 

 

WARNING

Instructions must be posted in a prominent location. All safety precautions 

must be taken in the event the user smells gas. Safety information can be obtained from 
your local gas supplier. 

                                                                 

 

  CAUTION: 

These  models  are  designed,  built,  and  sold  for  commercial  use  only.  If  these 

models  are  positioned  so  the  general  public  can  use  the  equipment,  make  sure  that 
cautions, warnings, and operating instructions are clearly posted near each unit so that 

 

  anyone using the equipment will use it correctly and not injure themselves or harm the     

 

  equipment. 

 
 

GAS PRESSURE 

The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected from 
the gas supply piping system during any pressure testing of that system at test pressures in excess 
of ½ psi (3.45 kPa). 
The appliance must be isolated from the gas supply piping system by closing its individual manual 
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to 
or less than ½ psi (3.45 kPa). 
 
 

WARNING

A factory authorized agent should handle all maintenance and repair. Before 

doing any maintenance or repair, contact your authorized service representative. 

 
 

Conforms to ANSI STD

Z83.11b-2009(R2012)

Certified to CSA 

STD 1.8b-2009(R2012)

Summary of Contents for CBL15

Page 1: ...as Safety information can be obtained from your local gas supplier CAUTION These models are designed built and sold for commercial use only If these models are positioned so the general public can use...

Page 2: ...l experience years of reliable operation from this equipment To ensure best results it is important that you read and follow the instructions in this manual carefully TABLE OF CONTENTS ITEM PAGE ITEM...

Page 3: ...ughly reads understands and follows these instructions If you have questions concerning the installation operation maintenance or service of this product visit Cooking Performance Group s website at w...

Page 4: ...N NON COMBUSTIBLE SURFACES ONLY Combustible clearances 6 sides 152 mm 6 rear 152 mm 4 oor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 oor 102 mm Do not obstruct the ow of combustion an...

Page 5: ...panel 1 Remove the knobs and front panel 2 Uns 2 Unscrew bolts and pilot valve then remove the manifold 1 Remove the knobs and front panel Note Unit Number on side of orifice fittings Plastic Insert...

Page 6: ...n the screws on the front of the burner and adjust the air shutter to just eliminate the yellow tips of the burner flame Lock the air shutter in place by tightening the screws CAUTION Never attempt to...

Page 7: ...supports Radiants should be centered over the straight section of the burners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 NOTE When co...

Page 8: ...t are not to be adjusted by the installer unless the installer is an authorized service agent TOUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on when valve is on Pilot burner not lit Ga...

Page 9: ...9 EXPLOSION VIEW DRAWING MODEL CBL24 CBR24...

Page 10: ...R48 8 2 Cast Radiant CBR15 01 03 1015048 2 CBR24 4 CBR36 6 CBR48 8 3 Regulator 6 NAT or 10 LP 3 4 PT CBL15 CBR15 01 22 1069501 1 CBL24 CBR24 CBL36 CBR36 CBL48 CBR48 4 Stainless Steel Burner Assy U Sha...

Page 11: ...t Pipe CBL15 CBR15 06 05 1472152 1 CBL24 CBR24 2 CBL36 CBR36 3 CBL48 CBR48 4 8 Pilot valve CBL15 CBR15 01 20 1068509 1 CBL24 CBR24 2 CBL36 CBR36 3 CBL48 CBR48 4 9 Valve For Manual CBL15 CBR15 01 20 10...

Page 12: ...e 49 LPG CBL15 CBR15 01 20 1068649 1 CBL24 CBR24 2 CBL36 CBR36 3 CBL48 CBR48 4 12 Cast Iron Lava Rack CBL15 01 03 1015106 2 CBL24 4 CBL36 6 CBL48 8 13 Lava Rock CBL15 06 05 1472464 1 CBL24 2 CBL36 3 C...

Page 13: ......

Page 14: ......

Page 15: ...V1 Rev1 12 14...

Page 16: ...e occurs because of accident carelessness lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and operating instruct...