REVISED 06/2022
User Manual
Salamander
Gas Broiler
Cooking Performance Group
.
https://www.cookingperformancegroup.com/
351S36SBL36K, 351S36SBL60K, 351S36SBLWK,
351S36SBN36K, 351S36SBN60K, 351S36SBNWK
4003027
Page 1: ...REVISED 06 2022 User Manual Salamander Gas Broiler Cooking Performance Group https www cookingperformancegroup com 351S36SBL36K 351S36SBL60K 351S36SBLWK 351S36SBN36K 351S36SBN60K 351S36SBNWK 4003027...
Page 2: ...g Performance Group ranges using the appropriate mounting kit Contents Product Overview 2 Safety Precautions 3 Assembly Instructions 4 7 Specifications 8 Start up Serial Plate 8 9 Gas Connection Eleva...
Page 3: ...or any other equipment Improper installation adjustment alteration service or maintenance could lead to property damage injury or death Read the installation operating and maintenance instructions tho...
Page 4: ...M8 x 24 Bolt B M8 x 60 Bolt C 4 15 Lock Washer M8 Flat Washer M8 Assembly Instructions STACKING 36 WIDE RANGE 1 Remove A bolts x4 flat washers x4 and lock washers x4 from backside of backsplash Keep...
Page 5: ...4 4 Remove original support brackets x2 and back plate assembly from range Discard original support brackets x2 5 Insert new support brackets x2 into U shaped brackets that original support brackets w...
Page 6: ...ashers x4 and lock washers x4 9 Before installation of the salamander remove the outer plastic film Remove and discard rubber feet from salamander x4 10 Lift salamander and place into backsplash assem...
Page 7: ...DE RANGE 1 Select a side to mount the salamander to the range It cannot be mounted in the center 2 Follow the same procedure as the 36 range as listed above WALL MOUNT 1 Secure top hanger plate A on s...
Page 8: ...ed with the included mounting kit by a licensed installer 3 Please install the included CPG gas regulator Failture to install this regulator may result in a voided warranty This unit is only applicabl...
Page 9: ...or propane gas it should only be connected to the type of gas for which it is equipped as stated on the serial plate 3 A 1 2 NPT inlet is located at the rear for the gas connection The external regula...
Page 10: ...ent is installed must be fitted with air intakes to guarantee the correct operation of the unit and air exchange 4 During Installation make sure the air suction and evacuation ways are free from any o...
Page 11: ...perating the device to avoid burnings Warnings 1 Always ensure proper supervision while the equipment is in use 2 Simple adjustments to knobs leg height etc do not require assistance from specialized...
Page 12: ...a wet cloth and soapy water solution or detergent solution as long as such solutions do not contain any acidic or alkaline substances Wipe with clean water and then dry with a clean cloth Do not use s...
Page 13: ...installed correctly verify arrow on regulator points towards to unit Make sure the dual gas regulator was setup to the correct gas being supplied to the unit There is a light back sound when turning...