CPflight B737 Series Manual Download Page 1

MCP737PRO3 

 

 

 

This manual is intended for Flight Simulator use only and may not be used in any 

real world aviation application. The authors are not responsible for any errors or omissions. 

 

FOREWORD 

 

Thank  you  for  purchasing the  CPflight  MCP737PRO3  hardware. To  optimize  the  performance  of 

this  unit,  please  read  through  this  manual  carefully.  This  manual  gives  you  the  information  to 

connect and use MCP737PRO3 panel with Microsoft Flight simulator, P3D, Project Magenta and 

other add-on software. Even if the MCP737PRO3 support the mainly used FS add-on software, it is 

not  possible  to  assure  the  full  compatibility  with  all  third  part  add-on.  To  know  more  about  the 

compatibility  with  a  specific  add-on  aircraft  please  refer  to  the  latest  “Compatibility  table”  at  the 

MCP737PRO3 product page on the CPflight website. 

Note:  This  manual  contains  the  latest  information  at  the  time  of  drafting.  Due  to  the  continuous 

evolving of the product some  features could be been modified. Eventual later information can be 

found at CPflight website www.cpflight.com 

The CPflight modules are produced to meet requirements from the hobby market. The use of our 

products  in  professional  or  commercial  environments  is  not  permitted  without  approval  of  the 

CPflight management; please contact us at [email protected] if you need to exploit our products in 

professional or commercial environments.  

MCP737PRO3  is  a  full  scale  replica  of  the  Boeing  737NG  Mode  Control  Panel,  look  and 

functionality are reproduced with high details. MCP737PRO3 is equipped with high new generation 

quality level components: Grayhill

®

 Optical encoders, ambient light sensor for the display brightness 

regulation, autothrottle ARM switch with electromagnetic disengage and bank selector knob gives a 

high fidelity performances  and  a never seen realism. Our MCP737PRO3 connects directly to the 

Ethernet using an Ethernet socket on the back of the panel (USB version on request). 

IMPORTANT NOTE: It is important to know that the hardware have not its own intelligence 

on board, it establishes an interface with the connected software; logics, operating modes 

and aircraft behavior are managed by the software itself.  

 

HARDWARE INSTALLATION 

The MCP737PRO3 is intended as a part to be inserted in a cockpit reproduction, CPflight does not 

produce chassis or other mechanical parts for the cockpit structure, so the panel is intended to be 

inserted  in  your  own  cockpit  glare  shield.  Fixing  screws  are  not  provided  as  depending  by  the 

thickness and/or material of your glare shield panel, different screws can be required.  

We suggest to maintain the accessibility to the back of the MCP located in your glareshield, to allow 

working to your connections. 

 

CONNECTIONS 

The  MCP  is  provided  with  a  universal  supply  adapter  that  accepts  a  voltage  of  100  to  240Vac 

(50/60Hz). Supply adapter and ethernet cable are provided with the MCP, you don’t need further 

hardware to operate.  

Sockets for connections are on the back of panel. Beyond the supply and ethernet connectors the 

MCP737PRO3 have some further sockets, they are provided to allow system expandability. A DIN 5 

pole socket “C” is used to link in daisy-chain auxiliary CPflight modules (EFIS selectors, MIP737ICS 

System, Radios etc).  

Close to ethernet socket, there is a small 6-pole terminal block ready for external backlight control, 

external A/T disengage pushbutton and external TO/GA pushbutton.  

 

Ethernet socket 

 

 

 

5 pole cable socket 

      terminal block 

 

 

WARNING! Do not attempt to connect anything different from as described in this section; 

warranty  does  not  cover  damages  due  to  incorrect  wiring  of  any  external  device.  The 

MCP737PRO3 is provided with 6Vdc power supply adapter. Only provided stabilized plug-in 

power supply adapter must be used; do not attempt to plug in a different adapter because 

you can damage the MCP. The provided adapter is suitable for 100 to 240 Vac 50/60Hz main 

supply.  

Note:

 

If  you  do  not  use  MCP  for  a  long  time  it  is  recommended  to  disconnect  the  power 

supply. 

 

 

 

 

 

 

ETHERNET CONNECTION  

INSTALLATION 

As default the MCP has the IP address 192.168.1.40. 
If  your  PC  is  already  connected  to  a  “home”  LAN 
trough a router probably will be not necessary to set 
anything.  Anyway  it  would  be  better  to  check  some 
Ethernet parameters:  

 

STEP 1 

1. Click the right button of the mouse on the Windows 
symbol. Please select “Control panel”.  

 

 

 

 

2/3. Click on “Network and Internet” indicated in the red oval and click on “ Ethernet” button in the 
red oval. 

 

 

 

4.  in  Ethernet  status  window  click  on  “Details”  button  and  the 
system  will  open  the  ethernet  connection  details  with  the  IPv4 
address. In  our example our IPv4 is 192.168.1.208; in order  to 
have  your  MCP  communicating  with  your  PC  is  necessary  to 
assign an IP number to your MCP. As default the MCP has the 
IP address 192.168.1.40. So is not necessary to assign any new 
IP number. If the two IP addresses would be identical it will be 
necessary  to modify  the MCP IP  address. How  to  do it  will  be 
explained in the programmation section.  

 

STEP 2 

If your PC is not connected to any LAN and your MCP is connected directly to the ethernet socket 
of your PC, please follow these steps: 

 

 

1.  the  PC  will  show  a  warning  on  the  symbol  of  the  WLAN 
connection  (red oval). 

  

 

 

 

 

2. Click with the right button of the mouse on the Windows button  and select LAN connections and 
the next screen will appear. Click on Ethernet.   

 

 

 

  

3. Click on “Properties” on the ethernet status window. Please flag on “Internet version 4 protocol 
(TCP/IPv4) on the red oval.                                                                                                                 
4.  Click  on  “Properties”  and  please  select  manually  the  address  192.168.1.100  flagging  “use 
following  IP  address”.  Selecting  subnet  mask  field  the  value  255.255.255.0  will  be  automatically 
inserted in it. Click on OK to save the changes.  

 

 

 

 

CONTROL ETHERNET CONNECTION 

 

 

 

 

 

 

1.  To  control  for  the  first  time  the  ethernet  connection  please  
click the right button of the mouse on the Windows symbol and 
select “execute”. 

2. Please write in the Execute window “cmd” and select ok. 

 

3

On  the  prompt  command  please  write 

ping  and  IP  address  of  your  MCP.  In  our  
example  the  MCP  IP  address  is 
192.168.1.40. If all is ok the number of the 
transmitted  packages  will  match  with  the 
one  of  the  transmitted.  Otherwise  this 
means that there is a  ethernet connection 
failure.  In  this  case  please  contact 

[email protected]

.  

 

COMMUNICATION SOFTWARE INSTALLATION 

Note: the communication software allows to use the MCP737PRO3 with default FS aircraft and the 
most  used  add-on  like  e.g.  PMDG737NGX,  iFly737  etc.  To  use  the  MCP737PRO3  with  PMDG 
series please read carefully the related instructions. 

To  allow  to  the  MCP  to  communicate  with  the  simulator  is  necessary  to  install  the  driver  of  the 
communication that are available on our website in the section “Technical and the software” on the 
MCP page.  
- Please download the file instfsx_xxx.zip or instP3d_xxx.zip (in base on the simulator environment 
used). Is essential to extract the exe file and install the driver 

under  

FSX or P3d folder.  

-   The  file is in a  compressed (zip) archive.  Extract in a  temporary folder and run the  exe  file  to 
install software (start PC as administrator to install software on all Windows OS versions). 
- CPflight  MCP  requires  the popular  FSUIPC library.  If  you  do  not  have FSUIPC in your system 
download it at  

http://www.schiratti.com/dowson.html

 

A/T ARM SWITCH 

MCP737PRO  comes  provided  with  electromagnetic  Autothrottle  ARM  switch.  The  switch 
automatically releases to the “Off” position after the landing touchdown or pressing an  

 

Reviews: