CPA AMBRA Manual Download Page 7

MANTEINANCE MANUAL

 

AMBRA 

pag. 7 di 8

 

www.cpa-piscine.it 

Ver01

 2021-06-18 

 

 

 

 

The vibrations of the machine. In case of anomaly, stop the machine immediately 

 

The state of deterioration of the components, periodically replacing those worn by normal use (eg 

O-rings, gaskets, bearings) 

 

In models with pre-filter, regularly clean the basket from the impurities collected to avoid 

pressure drops and motor overheating in case of obstruction of the suction mouth. 

 

 

 

 

enter 

exit 

 

clock
wise 

 
 

 
 
 
 
 

 

WINTERING 

fig. F 

fig. G 

Risk of freezing: if the pump remains at a temperature  of less than or equal to 0 ° C for a long 

time,  the  pump  body  must  be  completely  emptied  through  the  special  drain  located  below  the 
pump body in order to prevent breakage and damage to the hydraulic components (fig. G). Then 
clean with clean water, dry, remove and store in a dry place. The aforementioned operations are 
also  recommended  for  long  periods  of  inactivity  in  normal  temperature  conditions.  After  a  long 

period of inactivity, repeat all the operations described for the first start-up. 

 

PROBLEMS AND SOLUTIONS 
 

Problem 

Cause 

Solution 

The engine does not start 

Active thermal protection 

If the engine is overheated, it will remain 

inactive. It waits for it to cool for about 

20-30 minutes 

Damaged thermal protection 

Replacement with a new one 

Wrong wiring 

Check the connection making sure it is 

secure. 

          Repeat the connection 

Engine failure 

Conjtact a service center 

Impeller blocked 

Wash the impeller 

Insufficient voltage 

Check the voltage present on the line 

(qualified technical personnel) 

The engine runs without 
pumping water 

The water level in the suction 
basin is too low or lower than the 

suction point 

Check the water level in the basin 

Filter or shut-off valve 

obstructed 

Wash the elements 

Air bubbles in the suction pipe 

Check the tightness of the pipe 

joints. 

Check that the level of the intake 

valve is less than 50 cm compared 
to the free surface of the water 

base 

Summary of Contents for AMBRA

Page 1: ...MANTEINANCE MANUAL Ver 01 2021 06 18 Read carefully AMBRA Circulation water pump...

Page 2: ...p body cover and diffuser made of high quality plastic material Motor shaft in AISI 316 stainless steel Excellent and long lasting mechanical seal Seal support made of glass and polyamide Windings imp...

Page 3: ...2870 17 8 23 16 AMBRA 150M 230 50 6 1 1 5 1 1 2880 20 8 25 18 25 AMBRA 150T 400 50 2 7 3 1 5 1 1 2880 20 8 25 18 AMBRA 200M 230 50 7 1 2 1 5 2880 22 10 28 20 30 AMBRA 200T 400 50 3 1 3 2 1 5 2880 22...

Page 4: ...ith the installation check that the moving parts rotate freely insert a screwdriver into the recess of the motor shaft on the side of the fan protection grid and try to rotate the blades fig C If the...

Page 5: ...the formation of air pockets It is recommended to use a non return valve between the delivery port and the flow control valve in order to avoid dangerous water hammer in the event of a sudden stop of...

Page 6: ...f an accidental dry start immediately disconnect the power supply then wait for the engine to cool and then fill it with clean water Start the pump and check in the three phase version that the direct...

Page 7: ...lso recommended for long periods of inactivity in normal temperature conditions After a long period of inactivity repeat all the operations described for the first start up PROBLEMS AND SOLUTIONS Prob...

Page 8: ...ce of air Check the mechanical joint Transparent perforated plastic cover Clean the clear plastic cover and check the gasket Wrong motor direction Electrical check High absorption Adjust the absorptio...

Reviews: