The pump can be properly grounded by checking that the electrical connections and clamps 
are tight. The pump is able to support a voltage variation equal to ± 10% with respect to the 
nameplate data: failure to comply with this condition will result in a reduction in the useful life 

of the pump. Check the presence and correct positioning of the gasket in the wiring terminal 
box in order to avoid the accidental entry of water into the motor and into the live electrical 
parts. 

START 

Before  starting  the  pump  for  the  first  time,  check  the  calibration  of  the  electrical  protection 

devices of the motor and that the protective devices against electrical and mechanical contacts are 

correctly  positioned  and  fixed.  Do  not  use  the  pool  at  the  time  of  the  first  check  of  the  pump 

installation. 

Perform the following procedure to properly prime the pump before starting the pump: 

1.

 

Open the prefilter cover; 

2.

 

Fill the pump with clean water through the prefilter until the water comes out through

 

the intake duct; 

3.

 

If the basket moves during these operations, do not forget to place it again inside the 
prefilter  to  prevent  coarse-grained  particles  from  infiltrating  the  pump  which  could 
damage it; 

4.

 

Close  the  prefilter  checking  the  correct  coupling  of  the  cover  gasket  with  the  pump 

body. 

  

WARNING 

 

Dry running causes irreparable damage to the mechanical seal: in the event of an accidental dry 

start, immediately disconnect the power supply, then wait for the engine to cool and then fill it with 
clean water. Start the pump and check, in the three-phase version, that the direction of rotation is 
correct: this should be done clockwise when looking at the pump from the fan side. If this is not 

the case, invert the phases in the connection terminal after disconnecting the power supply to the 
pump  (fig.  C).  Avoid  contact,  even  accidental,  with  the  moving  parts  of  the  machine  during  its 
operation or before its complete stop. 

  

RACOMMENDATIONS 

 

The  pump  should  not  be  started  more  than  twenty  times  in  an  hour  so  that  the  motor  is  not 
subjected  to  excessive  thermal  stress.  Before  proceeding  with  any  maintenance  operation,  check 
that the machine is disconnected from the power supply and that the start-up devices are blocked. 

MAINTENANCE AND CLEANING 

Under normal use conditions the pump does not require maintenance operations, however it could 

be useful to clean the hydraulic parts if you notice a loss of pump efficiency. The pump must not be 

disassembled by unqualified personnel or by unauthorized technicians. 

In any case, all operations must be carried out only after having disconnected the pump from the 

electricity mains and after having turned off the ignition devices.. 

 

PERIODIC CHECKS 

         

Check periodically: 

-

 

The correct fastening of the mechanical components and the condition of the machine support screws 

-

 

The correct position, fastening and condition of the power conductors and insulating components 

-

 

The temperature of the machine and the electric motor. In the event of an anomaly, stop the machine 

immediately

Summary of Contents for AMBRA

Page 1: ...MANTEINANCE MANUAL Ver 01 2021 06 18 Read carefully AMBRA Circulation water pump...

Page 2: ...p body cover and diffuser made of high quality plastic material Motor shaft in AISI 316 stainless steel Excellent and long lasting mechanical seal Seal support made of glass and polyamide Windings imp...

Page 3: ...2870 17 8 23 16 AMBRA 150M 230 50 6 1 1 5 1 1 2880 20 8 25 18 25 AMBRA 150T 400 50 2 7 3 1 5 1 1 2880 20 8 25 18 AMBRA 200M 230 50 7 1 2 1 5 2880 22 10 28 20 30 AMBRA 200T 400 50 3 1 3 2 1 5 2880 22...

Page 4: ...ith the installation check that the moving parts rotate freely insert a screwdriver into the recess of the motor shaft on the side of the fan protection grid and try to rotate the blades fig C If the...

Page 5: ...the formation of air pockets It is recommended to use a non return valve between the delivery port and the flow control valve in order to avoid dangerous water hammer in the event of a sudden stop of...

Page 6: ...f an accidental dry start immediately disconnect the power supply then wait for the engine to cool and then fill it with clean water Start the pump and check in the three phase version that the direct...

Page 7: ...lso recommended for long periods of inactivity in normal temperature conditions After a long period of inactivity repeat all the operations described for the first start up PROBLEMS AND SOLUTIONS Prob...

Page 8: ...ce of air Check the mechanical joint Transparent perforated plastic cover Clean the clear plastic cover and check the gasket Wrong motor direction Electrical check High absorption Adjust the absorptio...

Reviews: