![COX EC80 User Manual Download Page 40](http://html1.mh-extra.com/html/cox/ec80/ec80_user-manual_2674291040.webp)
Flow processor Programming
April 2019
CXX-UM-03060-EN-01
Page 40
Option
Function
Manual Stop Manual stop begins data logging when you click
Start
and ends data logging when
you click
Stop
Timed Stop
(Seconds)
Timed stop (Seconds) begins data logging when you click
Start
and ends data logging
when it reaches the numerical value adjacent to the drop-down menu For Example,
if 100 were placed in the time field adjacent to the drop-down menu, 100 seconds
would elapse before the data would cease to log
Timed Stop
(Minutes)
Timed stop (Minutes) begins data logging when you click
Start
and ends data logging
when upon reaching the numerical value adjacent to the drop-down menu For
Example, if 100 were placed in the time field adjacent to the drop-down menu, 100
minutes would elapse before the data would cease to log
Timed Stop
(Date)
Timed stop (Date) begins data logging when you click
Start
and ends data logging
when upon reaching the numerical value adjacent to the drop-down menu For
Example, if 1/1/20 were placed in the time field adjacent to the drop-down menu, the
GUI would continue to log data until January 1st 2020
Sample Stop Sample stop begins data logging when you click
Start
The software logs one sample's
worth of data and stops at the set interval in the sample rate field
Viewing Log
To view the log being populated, click
View
You will be transferred to the logging
file you have designated Values update at the intervals set
Watching Log
To watch the log being populated in real-time, click
Watch
You will be transferred
to the logging file you have designated
FLOW PROCESSOR PROGRAMMING
Connect all sensors, transducers, pickups and com-link cables to the EC80 Flow
Processor before powering up the computer Communication needs to be
established with the EC80 Flow Processor prior to uploading or downloading
a profile All flow processors, unless specially configured, communicate via an
RS485 connection to the PC The PC, in conjunction with an RS485 converter is
required for communicating with the flow processor Ask your sales representative
regarding purchase of USB-to-RS485 converters (PN EF I-7561)
Downloading Profiles
Downloading a profile is how you use all the information you programmed into
the IFC GUI to program the flow processor Follow this procedure to download the
current profile to the flow processor:
1 Click the white box next to
Enable
on the tool bar
2 Click the
Download
icon All information in the data tables, either blank or
populated, is written to the flow processor