Withstand pressure
For your safety, please read the following before using.
ORDERING INFORMATION
0.6
MPa
Unit:mm
OUTPUT TYPE
1
HOW TO SET PRESSURE
H
Setting Pressure
Hys.
≦
3
% F.S.
Vacuum Pressure
3
1
4
CONNECTOR PINOUT
(1) Brown(+)
(3) Blue(–)
(4) Black(OUT)
4
5
6
7
1
2
3
8
Vacuum
10 mA max.
0.8V
±3% F.S. of detected pressure (25°C) at temp. Range of 0~50°C
Adjusting by VR
Operation: 0 ~ 60°C,
Storage: -20 ~ 70°C (No condensation or freezing)
M8 connection 3-pin (Cable L:150mm)
3% F.S. max.
Push-in tube or thread-in
Air, Non-corrosive/Non-flammable gas
80mA max.
Fluid
Power supply voltage
Current consumption
Sensor type
Ambient temp. range
Piping method
Hysteresis
Weight
Temperature characteristic
Setting method
Internal voltage drop
Load current
Approx.
1ms
Response time
10.8 to 30V DC (include ripple voltage)
Operation/Storage: 35 ~ 85% RH ( No condensation)
Ambient humidity range
IP 40
Enclosure
Yes
Output short circuit protection
Total amplitude 1.5mm,10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z
Vibration
±1% F.S.
Repeatability
Red LED turns ON
Indicator
980m/s
2
(100G), 3 times each in direction of X, Y and Z
Shock
PSK100 series
Set pressure range
SPECIFICATIONS
- 1
01.3 ~ 0 kPa
PR-0328
C
2022/0
3
Printing We reserve the right to change the specification without prior notice.
Vacuum managers
PSK100 M8
Approx. 8.3g (with M8, 3-pin male connector)
COVAL SAS - Vacuum Components - ZA des Petits Champs - 26120 Montélier - FRANCE - Tel +33 (0)4 75 59 91 91 www.coval.com
17.3
D6 :
Ø
6mm
20
29.5
M5:M5*0.8
Hex flat : 8mm
22.5
20
10.4
Hex flat : 10mm
G18:G1/8" (BSPP), M5
25.4
10
26
150
Use the pressure setting trimmer to set "ON" pressure.
Rotate clockwise to increase pressure setpoint .
Rotate counter-clockwise to decrease pressure setpoint .
Use appropriate size screwdriver for the setting trimmers.
Gently turn the screwdriver to make adjustments.
To prevent damage to the pressure setting trimmer,
DO NOT force the trimmer when it comes to a stop.
DIMENSIONS
CIRCUIT WIRING DIAGRAM
Do not use corrosive or flammable gas or liquid with this product.
Please use within the s
etting
pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage to
the pressure sensor may occur.
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and can cause
malfunction.
Turn power off before connecting wiring. Wrong wiring or short circuit will damage and / or cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.
Wiring for pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause
malfunction.
ESD protection ±4KV.
Electrical connection
With M8, 3Pin male connector
- : PNP output
N : NPN output
Vacuum (
- 1
01.3
~0
k
Pa)
Pressure Range
D
6:
Ø 6mm Tube
G18
:
G1/8"(BSPP), M5
M5
:
M5*0.8
Pressure Port
Wiring Type
Output Specifications
P S K 1 0 0 G 1 8 M 8 N
Switch
main
circuit
Red
Brown
Black
Blue
R
L
OUT
DC(–)
DC10.8~30V
DC(+)
NPN
Switch
main
circuit
Red
Brown
Black
Blue
DC10.8~30V
OUT
PNP
R
L
DC(–)
DC(+)
PNP / NPN
PAP
22