XM6: CONTROLS & INDICATORS
11 Parallel Input Switches – “IN”: Each appropriate switch must be set
to the “IN” position when the source unit does not supply rear or
subwoofer channel outputs. “OUT”: If the source unit has independent
front, rear and/or sub channel outputs, set each switch to the “OUT”
position
12 High-Pass Frequency Selectors – For selection of high-pass crossover
frequency between 40Hz and 400Hz, 18dB/Octave
13 Frequency Multiplier – To change selected high-pass crossover
frequencies from 40Hz - 400Hz, to 800Hz - 8000Hz, 18dB/Octave
14 Band Pass Switch – Positioning this switch to the “IN” position reconfig-
ures the “B” channel from a high pass output to a band pass output.
When the “IN” position is selected, the band pass frequency selector is
engaged.
15 Band Pass Frequency Selector – For selection of the top crossover point
of the band-pass frequency range between 300Hz and 3kHz,
18dB/Octave. (The high pass frequency selector must be used to
select the bottom crossover point for the band-pass frequency range.)
The full band pass frequency range is 40Hz to 3kHz, 18dB/Octave.
16 Subwoofer Frequency Selector – For selection of the low-pass crossover
frequency between 40Hz and 200Hz, 36dB/Octave
17 Bass Shaper Frequency Selector – For selection of low frequency
equalization point between 40Hz - 100Hz.
18 Bass Shaper Boost Level Control – For adjusting the Bass Shapers
selected equalization frequency level with a maximum boost of 18dB
19 Phase Control Switch – Positioning the switch to the “180”
position shifts the right output signals on channels “A” and/or “B”
180 degrees out of phase relative to their left output signals
20 Sub Phase Control Switch – Positioning the switch to the “180”
position shifts the subwoofer output signals 180 degrees out of phase
relative to channels “A” and “B” output signals
21 Independent Output Level Controls – Independent left and right output
signal level adjustments can be made for accurate stereo balance and
imaging
22 Subwoofer Output Level Control – For adjusting the low pass output
signal level
23 Power Indicator – This indicator lights up when the internal switching
power supply is activated and the unit is operational
WWW.COUSTIC.COM
9
11
11
12
12
13
16
14
21
21
17
18
22
23
15
19
19
20
XM6 CONTROL PANEL