If the new disinfectant is not compatible with the previous
one, then the tank should be filled with water or an adequate
solvent and emptied the (see 9. END OF OPERATION).
▪
Disinfectant liquids usually need to be diluted in water
(following the instructions of the disinfectant manufacturer).
You can fill your
Counterfog® PILAR
with the diluted solution
or alternatively to fill it with the several components according
to the corresponding proportions.
Always wear gloves and safety glasses when filling the tank!
Do not overfill! This will damage the device.
o
When finish pouring the liquid, close the filling valve (
Close 3
“FILL”
).
o
Screw the cap to the funnel (
screw 12
).
o
Close and lock the vent valve (
Close
11 “VENT”
).
5.3
POWER CONNECTION
Before making electrical connections carefully check that the voltage supplied is
compatible with the voltage marked on the data plate and that there are shortcut
and overcurrent as well as current default protections in service
o
Double check
all valves (
3 “FILL”, 4 “EMPTY”
,
6 “LIQUID”
,
7 “AIR” and 11
“VENT”
) are closed
.
o
Double check the
two switches
at the top of
Counterfog® PILAR
are
OFF
.
o
Plug the equipment
to the 120 V/60 Hz supply line.
5.4
SWITCH ON AND PRESSURIZATION OF TANK
o
Activate the switch on the left (
Activate switch 1
) (
yellow arrow in the figure
)
which activates the fan.
o
Activate the switch on the right (
Activate switch 2
) (
green arrow in the figure
)
which activates the compressor.